Search all medical codes

Mass spectrometry and tandem mass spectrometry (eg, MS, MS/MS, MALDI, MS-TOF, QTOF), non-drug analyte(s) not elsewhere specified, qualitative or quantitative, each specimen

CPT4 code

Name of the Procedure:

Mass Spectrometry and Tandem Mass Spectrometry (e.g., MS, MS/MS, MALDI, MS-TOF, QTOF)

Summary

Mass spectrometry (MS) and tandem mass spectrometry (MS/MS) are advanced analytical techniques used to identify and quantify different molecules in a specimen. This includes variants like Matrix-Assisted Laser Desorption/Ionization (MALDI), Time of Flight (TOF), and Quadrupole Time of Flight (QTOF) mass spectrometry, which employ different methods to ensure accurate measurement of molecular compositions.

Purpose

Mass spectrometry is used to identify unknown compounds, confirm the presence of specific molecules, and provide detailed data on their structure and quantity. It is crucial in diagnosing various medical conditions, analyzing biological specimens, and conducting research in biochemistry and pharmacology.

Indications

  • Unexplained symptoms that may relate to metabolic disorders.
  • Toxicology screening to detect potential toxins or drugs.
  • Investigating genetic disorders and protein malfunctions.
  • Monitoring biomarkers for disease processes or therapeutic efficacy.

Preparation

  • Patients may be advised to fast for several hours before the procedure depending on the test requirements.
  • They might need to avoid certain medications that could interfere with the results.
  • Preliminary diagnostic tests like blood or urine tests may be required to gather comprehensive data.

Procedure Description

  1. Sample Collection: A specimen such as blood, urine, or tissue is collected.
  2. Sample Preparation: The sample is then prepared by processes like centrifugation or dilution.
  3. Ionization: The molecules in the sample are ionized using techniques like MALDI.
  4. Mass Analysis: Ionized molecules are passed through a mass analyzer (TOF, QTOF) which separates them based on their mass-to-charge ratio.
  5. Detection: The ions are detected, and their mass spectrum is recorded.
  6. Data Analysis: The resulting data is analyzed to identify and quantify the components.

No anesthesia or sedation is required for the mass spectrometry itself, though sample collection might involve mild discomfort.

Duration

The entire process generally takes from a few minutes to a couple of hours, depending on the complexity of the analysis.

Setting

Typically performed in specialized laboratories or diagnostic centers equipped with the necessary instruments.

Personnel

  • Clinical laboratory scientists or technologists.
  • Biochemists or chemists specialized in mass spectrometry.

Risks and Complications

  • Minimal risk involved in the sample collection, such as slight discomfort or bruising.
  • Rarely, technical errors may lead to inaccurate results, which could necessitate repeat testing.

Benefits

  • Provides precise and highly detailed information about molecular compositions.
  • Can detect abnormalities that are not identifiable by other methods.
  • Quick turnaround time for results in emergency situations.

Recovery

  • No major recovery needed after the specimen collection.
  • Patients can resume normal activities immediately unless instructed otherwise for specific conditions.

Alternatives

  • Enzyme assays and immunoassays for specific proteins.
  • Gas chromatography for volatile compounds.
  • High-performance liquid chromatography (HPLC) for separation of non-volatile compounds.

    Each alternative has its own set of advantages and limitations based on the type of analysis required.

Patient Experience

  • During specimen collection, patients may experience mild discomfort.
  • The mass spectrometry process itself is not experienced by the patient, as it is performed on the collected specimen in a lab.
  • Any pain or discomfort from sample collection is generally minimal and short-lived.

Patients might receive results during a follow-up visit, where the findings and subsequent steps will be discussed.

Medical Policies and Guidelines for Mass spectrometry and tandem mass spectrometry (eg, MS, MS/MS, MALDI, MS-TOF, QTOF), non-drug analyte(s) not elsewhere specified, qualitative or quantitative, each specimen

Related policies from health plans

Similar Codes