Clinical Policy: Implantable Wireless Pulmonary Artery Pressure Monitoring

Indications

(10001) Is the procedure being requested for the CardioMEMS HF System? 
(10002) Is the CardioMEMS HF System made by St. Jude Medical? 
(20001) Is the patient classified as NYHA Class III heart failure? 
(30001) Has the patient been hospitalized? 
(30002) Was the hospitalization for heart failure? 

YesNoN/A
YesNoN/A
YesNoN/A

Sign up to see the rest of the questions

Unlock the remaining questions and the full coverage workflow.

Sign up for free
Effective Date

NA

Last Reviewed

NA

Original Document

  Reference



Clinical Policy: Implantable Wireless Pulmonary Artery Pressure Monitoring Reference Number: OH.CP.MP.160 Coding Implications

Date of Last Revision: 10/25 Revision Log

See Important Reminder at the end of this policy for important regulatory and legal information.

Policy Statement In compliance with Ohio Medicaid, Buckeye Health Plan must ensure coverage of medically necessary procedures. The plan covers all the services in the amount, duration, and scope that is no less than that covered by FFS Ohio Medicaid and in accordance with 42 CFR 438.210, with limitations, exclusions, and clarifications provided in the Ohio Medicaid Managed Care Provider Agreement and the Ohio Administrative Code.

Procedure

  • Buckeye Health Plan will not impose hard limits or restrictions on coverage of medically necessary services.
  • Prior to making determinations regarding coverage of services and procedures, Buckeye Health Plan will conduct a medical necessity review for all requests to include non- covered services and any request for services over an established benefit(s).

Description Various cardiac hemodynamic monitoring techniques have been investigated as a means to remotely guide outpatient heart failure (HF) therapy, including implantable wireless pulmonary artery (PA) pressure monitoring (e.g. CardioMEMS®).⁵ The implanted device measures and monitors daily PA pressure. The data is used by physicians for heart failure management with the goal of reducing heart failure hospitalizations.⁵ Currently, only CardioMEMS has FDA approval, and other devices (e.g. Chronicle®, ImPressure®) that monitor cardiac output through measurements of pressure changes in the pulmonary artery or right ventricular outflow tract are not supported by current evidence.⁷

Policy/Criteria I. It is the policy of Buckeye Health Plan and health plans affiliated with Centene Corporation® that the long-term safety and effectiveness of implantable wireless pulmonary artery pressure monitoring has not been proven for any indication, including the management of heart failure.

Background Heart failure (HF) is one of the most common causes of hospitalization and readmission.⁶,⁸ According to the Centers for Disease Control, an estimated 5.7 million adults in the United States have HF. HF is a complex clinical syndrome that results from any structural or functional impairment of ventricular filling or ejection of blood.⁹ The primary manifestations of HF are CLINICAL POLICY Implantable Wireless Pulmonary Artery Pressure Monitoring

dyspnea and fatigue, which may limit exercise tolerance, and fluid retention, which may lead to pulmonary and/or splanchnic congestion and/or peripheral edema.¹⁰,¹¹ The classification system most commonly used to quantify the degree of functional limitation caused by HF is the New York Heart Association Functional Classification system (NYHA).¹¹ This system assigns patients to one of four functional classes, depending on the degree of effort needed to elicit symptoms.¹¹

Accurate monitoring of HF patients for exacerbations is important in an effort to reduce recurrent hospitalizations and associated complications.¹² Strategies to reduce hospitalizations in patients with HF include optimizing evidence-based drug and device therapies, addressing causes of HF, treating comorbidities, and improving management of care.¹³ It is proposed that monitoring changes in pulmonary artery (PA) pressure (i.e., pressure the heart must exert to pump blood from the heart through the arteries of the lungs) may provide a way to monitor changes in HF resulting in improved HF management.⁶

The CardioMEMS HF System (St. Jude Medical) is Food and Drug Administration (FDA) approved for wirelessly measuring and monitoring pulmonary artery pressure and heart rate in NYHA Class III heart failure patients who have been hospitalized for heart failure in the previous year.⁶,⁷ The hemodynamic data is used by physicians for heart failure management with the goal of reducing hospitalizations related to heart failure.¹²

The CardioMEMS HF system provides daily PA pressure measurements, including systolic, diastolic, and mean PA pressures.⁵ The system includes a dime sized PA sensor that is permanently implanted in the pulmonary artery via fluoroscopy-guided right-heart catheterization, a transvenous catheter delivery system, a patient home monitoring electronic system, and a secure internet-accessible database that allows clinicians to access patient data.¹²,¹⁴ The home monitoring components include a pillow containing the antenna to capture the sensor reading, a bedside monitoring unit to which the pillow is connected via a cable, and a remote button. Each reading captures 18 seconds of pressure data that is wirelessly transmitted to a secure database. The patient’s physician can use this information to optimize medical management and potentially reduce the need for HF-related hospitalizations.⁵ The CardioMEMS HF System is contraindicated for patients with an inability to take dual antiplatelet or anticoagulants for one month post implant.

Sponsored by the manufacturer, the largest randomized single-blind trial, the Champion Trial (CardioMEMS Heart Sensor Allows Monitoring of Pressure to Improve Outcomes In NYHA Class III Heart Failure Patients), reported that transmission of PA pressure data from the device reduced HF-related hospitalizations at six months (31% versus 44%).¹⁵ A later analysis reported sustained reduction in HF-related hospitalization in the device-guided management group compared with the control at 18-month average follow-up (46% versus 68%).¹⁸ During a subsequent open access period with a mean duration of 13 months, pulmonary artery pressure information was made available to guide therapy in the former control group. The rate of admission was reduced compared with that in the control group during the randomized access period (36% versus 68%). The rate of device-related or system-related complications was 1%, which was also the rate of procedure-related adverse events. However, concerns were raised by the FDA regarding potential influence of the sponsor during the randomization period in this study.¹⁶,¹⁹-²⁰ In addition, study limitations include the lack of power to perform mortality analyses, lack of baseline quality-of-life data, and potential for sponsor to influence patient management.¹⁹ CLINICAL POLICY Implantable Wireless Pulmonary Artery Pressure Monitoring

At this time, the current evidence is insufficient to support the use of ambulatory cardiac hemodynamic monitoring using an implantable pulmonary artery pressure measurement device in individuals with heart failure in an outpatient setting. Data on long-term health benefits (including survival), safety issues, and quality of life are lacking. In addition, there is a lack of evidence on the accuracy and clinical utility of the device for use in other NYHA functional classifications.

American College of Cardiology Foundation The American College of Cardiology Foundation/American Heart Association (ACCF/AHA) 2022 Guidelines for the Diagnosis and Management of Heart Failure in Adults recommend monitoring with a pulmonary artery catheter in patients with respiratory distress or impaired systemic perfusion when clinical assessment is inadequate.¹⁰ In addition, invasive hemodynamic monitoring can be beneficial in certain patients with acute HF with persistent symptoms and/or when hemodynamics are uncertain.¹⁰

The ACCF/AHA guidelines do not specifically address outpatient wireless implantable pulmonary artery pressure monitoring, however, they note, “There has been no established role for routine or periodic invasive hemodynamic measurements in the management of HF. Most drugs used for the treatment of HF are prescribed on the basis of their ability to improve symptoms or survival rather than their effect on hemodynamic variables. The initial and target doses of these drugs are generally selected on the basis of controlled trial experience rather than changes produced in cardiac output or pulmonary capillary wedge pressure.”¹⁰

European Society of Cardiology According to the European Society of Cardiology (ESC), monitoring of pulmonary artery pressures using a wireless implantable hemodynamic monitoring system (CardioMEMS) may be considered in symptomatic patients with HF with previous HF hospitalization in order to reduce the risk of recurrent HF hospitalization.²¹ This recommendation from ESC is considered a Class IIB, level B recommendation (i.e., usefulness/efficacy is less well established by evidence/opinion, and data has been derived from a single randomized clinical trial or large nonrandomized studies).²¹

National Institute for Health and Care Excellence (NICE) Current evidence on the safety and efficacy of the insertion and use of implantable pulmonary artery pressure monitors in chronic heart failure is limited in both quality and quantity. Therefore, this procedure should only be used with special arrangements for clinical governance, consent and audit or research.²¹

Coding Implications Codes referenced in this clinical policy are for informational purposes only. Inclusion or exclusion of any codes does not guarantee coverage. Providers should reference the most up-to- date sources of professional coding guidance prior to the submission of claims for reimbursement of covered services. CLINICAL POLICY Implantable Wireless Pulmonary Artery Pressure Monitoring

CPT® Codes Description
33289 Transcatheter implantation of wireless pulmonary artery pressure sensor for longterm hemodynamic monitoring, including deployment and calibration of the sensor, right heart catheterization, selective pulmonary catheterization, radiological supervision and interpretation, and pulmonary artery angiography, when performed
93264 Remote monitoring of a wireless pulmonary artery pressure sensor for up to 30 days, including at least weekly downloads of pulmonary artery pressure recordings, interpretation(s), trend analysis, and report(s) by a physician or other qualified health care professional
HCPCS Codes Description
C2624 Implantable wireless pulmonary artery pressure sensor with delivery catheter, including all system components
Reviews, Revisions, and Approvals Revision Date Approval Date
Policy created and approved. 04/18 04/18
Centene Policy CP.MP. updated with OH Addendum . 11/22 12/22
Annual Review. ICD-10 Codes removed. References reviewed and updated. Policy moved to Ohio Specific template and Addendum language integrated into policy template as Policy Statement and Procedure. No material changes to review criteria. 07/23 07/23
Annual review. References reviewed and updated. Reviewed by external specialist. 07/24 09/24
Annual review. Policy/Criteria updated with no clinical impact. Background updated with no clinical impact. References reviewed and updated. 10/25
Book a walkthrough

Walk through this policy with us

Review how this policy can be converted into cited criteria, prior authorization checks, and operational automation.