Search all medical codes

Blood glucose monitor with integrated voice synthesizer

HCPCS code

Name of the Procedure:

Blood Glucose Monitor with Integrated Voice Synthesizer (E2100)

Summary

The Blood Glucose Monitor with Integrated Voice Synthesizer (E2100) is a device designed to help individuals with diabetes manage their blood sugar levels. It features auditory feedback to guide users through the testing process, making it accessible for patients with visual impairments.

Purpose

This device is used to measure blood glucose levels in patients with diabetes. The goal is to provide accurate readings that help patients and healthcare providers manage diabetes effectively, preventing complications such as hyperglycemia and hypoglycemia.

Indications

  • Diabetes (Type 1 or Type 2)
  • Visually impaired diabetes patients
  • Patients needing frequent blood glucose monitoring

Preparation

Patients are generally instructed to wash their hands thoroughly before performing a blood glucose test. No other special preparations are typically required, although patients should follow any specific instructions from their healthcare provider.

Procedure Description

  1. Handwashing: Patient washes hands with soap and water.
  2. Device Setup: Turn on the blood glucose monitor. The device will provide auditory instructions.
  3. Preparation of Test Strip: Insert a test strip into the monitor.
  4. Lancing: Using the lancing device, prick the fingertip to obtain a small blood sample.
  5. Application of Blood: Apply the blood sample to the test strip.
  6. Reading: The monitor will measure the blood glucose level and announce the result audibly.

Tools and Equipment:

  • Blood glucose monitor (E2100)
  • Test strips
  • Lancing device
  • Lancets

No anesthesia or sedation is required.

Duration

The entire process typically takes about 2-5 minutes.

Setting

This procedure can be performed at home, in a doctor’s office, or in a clinical setting.

Personnel

For routine home monitoring, no healthcare personnel are needed. In a clinical setting, a nurse or diabetes educator may assist.

Risks and Complications

  • Minor pain or discomfort from the finger prick
  • Slight risk of infection at the prick site

Benefits

  • Accurate monitoring of blood glucose levels
  • Enhanced accessibility for visually impaired patients
  • Immediate, audible feedback Expected benefits are realized immediately upon use.

Recovery

No specific recovery time is needed. Patients can resume normal activities immediately after testing. Regular monitoring as per the healthcare provider’s advice is crucial.

Alternatives

  • Standard blood glucose monitors without voice synthesizers
  • Continuous glucose monitors (CGMs) Pros and Cons: Standard monitors may be less accessible for visually impaired, while CGMs provide continuous monitoring but can be more expensive and complex.

Patient Experience

During the procedure, the patient may feel a slight prick when lancing the finger, but it is generally quick and minor. Pain management is not typically needed. The voice synthesizer feature enhances usability and comfort for those with visual impairments.

Medical Policies and Guidelines for Blood glucose monitor with integrated voice synthesizer

Related policies from health plans

Similar Codes