Ophthalmic Biometry for Intraocular Lens Power Calculation Form

Chat with GenHealth to automate any policy or prior auth task.


A-Scan Ultrasound Ophthalmic Biometry

Notes: If unilateral cataract extraction with IOL is planned, a bilateral technical component is typically performed while the professional component is unilateral. A second complete A-scan will be covered if it's performed by a different unaffilated surgeon on the second eye.

Indications

(394029) Is the patient undergoing cataract surgery? 
(394030) Does the patient have simple cataracts? 
(394031) Is there documentation of a significant change in vision at less than twelve months since the last scan? 

Contraindications

(394032) Has ophthalmic biometry already been performed within the past twelve months without a documented significant change in vision? 
(394033) Did an optometrist perform the previous biometry without coordination with the operating surgeon, resulting in the need for a repeat procedure by the surgeon due to inadequacy of the study? 
YesNoN/A
YesNoN/A
YesNoN/A

Sign up to see the rest of the questions

Unlock the remaining questions and the full coverage workflow.

Sign up for free
Effective Date

09/19/2019

Last Reviewed

09/11/2019

Original Document

  Reference



Background for this Policy

Summary Of Evidence

N/A

Analysis of Evidence

N/A

Abstract:

There are two methods used for intraocular lens power calculation:

  • A-Scan Ultrasound Ophthalmic Biometry

    Ophthalmic A-scan biometry by ultrasound echography is performed through the optical axis of the eye to determine the power of an intraocular (IOL) lens implant. The technical portion of ophthalmic biometry is usually performed in both eyes at the same setting.

  • Non-Ultrasound Ophthalmic Biometry

    Optical coherence biometry (OCB) utilizes partial coherence interferometry for measuring axial length (biometry) and for intraocular lens power calculation when planning for cataract surgery. OCB also measures the corneal curvature and anterior chamber depth. The technical portion is usually performed in both eyes at the same visit.

Indications:

A diagnostic ultrasound A-scan generally is used for patients who have simple cataracts. For patients with a dense cataract, an ultrasound B-scan may be used. (CMS Publication 100-03, Medicare National Coverage Determinations(NCD)Manual, Chapter 1, Part 1, Section 10.1) 

A second complete A scan/OCB will be covered if a different surgeon, unaffiliated with the surgeon who performed the first cataract extraction, performed the extraction on the second eye. We would not anticipate a high frequency of these instances.

Limitations:

Currently, the relative value units (RVUs) for the global and technical components of each method of ophthalmic biometry for intraocular lens power calculation are based on the procedure being bilaterally performed. If unilateral cataract extraction with an IOL implant is planned, a bilateral technical component of the A-scan or OCB is typically performed, while the professional component of the power calculation is performed unilaterally (on the operative eye only). Thus, the technical components are considered bilateral and the professional component is considered unilateral.

Prior to cataract surgery on the second, contralateral eye, allowance for the power calculation can be made. However, allowance for the technical component of the A-scan or OCB CPT code cannot be made since this bilateral procedure was performed and reimbursed at the time of the first surgery.

The technical component of the scan will generally provide valid information for twelve months. A repeat scan in less than twelve months would not be covered without documentation of significant change in vision (unless required because a second unaffiliated surgeon performed the second cataract extraction.) Generally, when bilateral cataracts are noted at examination, extraction of the second cataract is only performed after results of the first cataract extraction are known and symptoms or findings support the medical necessity for removal of the cataract in the other eye. If ophthalmic biometry is performed and later the surgery is canceled, it is reasonable to allow a repeat scan if significant time, e.g., greater than one (1) year, has elapsed when surgery is rescheduled.

Ophthalmic biometry for lens power calculation should not be performed unless a decision to remove the cataract has been made by the patient and surgeon. If the biometry is performed by an optometrist, he/she should do so in coordination with the operating surgeon so that only one procedure is necessary. If the biometry is repeated by the operating surgeon due to inadequacy of the study, the original eye care physician/provider should anticipate not being reimbursed for the study.


Book a walkthrough

Walk through this policy with us

Review how this policy can be converted into cited criteria, prior authorization checks, and operational automation.