Oral Appliances and Medical Management for Sleep Apnea Form
500 EXCHANGE STREET, PROVIDENCE, RI 02903-2699 MEDICAL COVERAGE POLICY | 1 (401) 274-4848 WWW.BCBSRI.COM
EFFECTIVE DATE: 08|01|2022 POLICY LAST REVIEWED: 09|17|2025
OVERVIEW Obstructive sleep apnea (OSA) syndrome is characterized by repetitive episodes of upper airway obstruction due to the collapse of the upper airway during sleep. Medical management of OSA may include weight loss, avoidance of stimulants, body position adjustment, oral appliances, and use of continuous positive airway pressure (CPAP) during sleep. Novel treatments include nasal expiratory positive airway pressure (EPAP) and oral pressure therapy.
MEDICAL CRITERIA Not applicable
PRIOR AUTHORIZATION Not applicable
POLICY STATEMENT Medicare Advantage Plans and Commercial Products Intraoral appliances for use in the treatment of documented mild to moderate obstructive sleep apnea are covered under the member’s durable medical equipment service when rendered by doctors trained in oral sleep appliances.
Other oral appliances used to treat conditions such as temporomandibular joint disease (TMJ) or bruxism (grinding or clenching of teeth) are considered non-covered service for all product lines.
Oral appliances for OSA that are available over the counter are not covered as they have not shown to be as effective as custom-fitted oral appliances in the treatment of OSA.
Devices for the treatment of snoring, not associated with sleep apnea, are not covered.
Medicare Advantage Plans and Commercial Products
The following services/devices are not covered for Medicare Advantage and not medically necessary for
Commercial Products as the evidence is insufficient to determine the effects of the technology on health
outcomes:
•
Use of a sleep positioning trainer with vibration for the treatment of positional OSA
•
Use of neuromuscular electrical stimulation of the tongue
•
Palate and mandible expansion devices
•
Nasal expiratory positive airway pressure and oral pressure therapy devices
COVERAGE Benefits may vary between groups/contracts. Please refer to the appropriate Benefit Booklet, Evidence of Coverage, or Subscriber Agreement for the applicable “Medical Equipment, Medical Supplies, and Prosthetic Devices, Diagnostic Imaging, Lab, and Machine Tests” benefit/coverage.
The fitting of the appliance and the appliance itself will be provided by a dentist/orthodontist who is experienced in the making of these devices.
Note: Medical Coverage Policy | Oral Appliances and Medical Management for Sleep Apnea
500 EXCHANGE STREET, PROVIDENCE, RI 02903-2699 MEDICAL COVERAGE POLICY | 2 (401) 274-4848 WWW.BCBSRI.COM
The following services associated with the oral appliance are considered inclusive in the global fee for the
device:
• Initial evaluation
• Oral/dental impressions
• Fabrication of the appliance
• Initial fitting, patient education, and teaching of use of the device
• Three follow-up visits once patient has begun to use the device*
*For individuals who are found not to be appropriate candidates for the appliance following the initial consultation, the provider may file for the appropriate evaluation and management code for the assessment of that patient.
**Additional visits, after the three follow-up visits, are the responsibility of the member unless an additional device is supplied.
A set of cephalometric X-rays (with and without the appliance) may be billed separately and are reimbursable. These services will be provided as diagnostic testing services.
The member will be responsible for any applicable durable medical equipment (DME) benefit copayments, coinsurance, and/or deductibles.
There is no waiting period for an oral appliance when a member has a CPAP.
Replacement and Repairs Replacement appliances and repairs are covered as medically necessary according to the “Durable Medical Equipment Repair and Replacement” policy. Medical review/preauthorization is not required for repair/replacement as the initial services do not require medical review/preauthorization.
BACKGROUND Obstructive sleep apnea syndrome is characterized by repetitive episodes of upper airway obstruction due to the collapse of the upper airway during sleep. This causes a drop in blood oxygenation and a brief arousal and can occur as frequently as every minute throughout the night. The most common signs and symptoms in adults are snoring, excessive daytime sleepiness, and hypertension. Excessive daytime sleepiness may be subjective, and is assessed by questionnaires such as the Epworth Sleepiness Scale, a short self-administered questionnaire that asks patients how likely they are to fall asleep in different scenarios such as watching TV, sitting quietly in a car, or sitting and talking to someone. Daytime sleepiness is uncommon in young children with OSA. Symptoms in children may include disturbed sleep and daytime neurobehavioral problems. In otherwise healthy children, OSA is usually associated with adenotonsillar hypertrophy and/or obesity.
A hallmark sign of OSA is snoring. The snoring abruptly ceases during the apneic episodes and during the brief period of patient arousal and then resumes when the patient again falls asleep. Upper airway resistance syndrome is a variant of OSA that is characterized by a partial collapse of the airway, resulting in increased resistance to airflow. The increased respiratory effort is associated with multiple sleep fragmentations, as measured by very short alpha electroencephalographic (EEG) arousals (“respiratory event-related arousals” [RERAs]). The sleep fragmentation associated with repeated arousal during sleep can lead to impairment of daytime activity. Adult patients with OSA-associated daytime somnolence are thought to be at higher risk for accidents involving motorized vehicles, i.e., cars, trucks, or heavy equipment. OSA in children may result in neurocognitive impairment and behavioral problems.
OSA can also affect the cardiovascular and pulmonary systems. For example, apnea leads to periods of hypoxemia, alveolar hypoventilation, hypercapnia, and acidosis. This in turn can cause systemic hypertension, cardiac arrhythmias, pulmonary hypertension, and cor pulmonale. Systemic hypertension is common in patients with OSA. Severe OSA is also associated with decreased survival, presumably related to severe hypoxemia, hypertension, or an increase in automobile accidents related to daytime sleepiness. It is estimated
500 EXCHANGE STREET, PROVIDENCE, RI 02903-2699 MEDICAL COVERAGE POLICY | 3 (401) 274-4848 WWW.BCBSRI.COM
that about 7% of adults have moderate or severe OSA, and 20% have at least mild OSA and that the referral population of OSA patients represents a small proportion of patients who have clinically significant and treatable disease.
Medical management of OSA in adults may include weight loss, avoidance of stimulants, body position adjustment, oral appliances, and use of various types of positive airway pressure (PAP) therapy (i.e., fixed CPAP, bilevel PAP [BiPAP], or auto-adjusting positive airway pressure [APAP]) during sleep.
Oral appliances can be broadly categorized as mandibular advancing/positioning devices or tongue-retaining devices. Oral appliances can either be “off the shelf” or custom made for the patient by a dental laboratory or similar provider.
Following appropriate radiological examinations, the oral device should be fitted by personnel trained and experienced in the overall management of oral health. To ensure the therapeutic benefit of the appliance, the patient should undergo follow-up examinations, adjustments of the device, and a follow-up polysomnography. The appliances themselves are categorized by Medicare as durable medical equipment (DME) and are not dental devices.
A systematic review of the evidence on the treatment of OSA with oral appliance therapy showed that oral appliances had no significant effect on sleep architecture and sleep efficiency. Meta-analysis found CPAP to be more effective than oral appliances, supporting the use of CPAP as a first-line therapy for treating OSA.
Nasal Expiratory Positive Airway Pressure, Oral Pressure Therapy, Sleep Positioning Trainer with
Vibration and Daytime Electrical Stimulation of the Tongue
The Daytime-Nighttime (DNA) Appliance and the mandibular Repositioning Nighttime Appliance (mRNA
Appliance) are customized palate and mandible expanding devices. In addition to the upper-jaw device that is
common to both the DNA Appliance and the mRNA Appliance (worn both during the day and night), the
mRNA Appliance moves the mandible forward and is worn during sleep. The DNA
Appliance and mRNA Appliance systems use 3-dimensional axial springs, which are proposed to gradually
expand the upper and lower jaw and airway to treat and eventually eliminate mild-to-moderate OSA.
eXciteOSA (Signifier Medical Technologies) uses daytime neuromuscular stimulation of the tongue to increase muscle tone with the goal of reducing snoring and mild sleep apnea.
NightBalance Sleep Positioning Trainer (Phillips) provides vibration whenever an individual with positional OSA is supine in order to trigger a change in body position.
Other devices that are being marketed for the treatment of OSA are PROVENT and Winx™. PROVENT is a single use nasal expiratory resistance valve device containing valves that are inserted into the nostrils and secured with adhesive. The Winx™ system uses oral pressure therapy (OPT) for the treatment of OSA. OPT provides light negative pressure to the oral cavity by using a flexible mouthpiece connected to a bedside console that delivers negative pressure. This device is proposed to increase the size of the retropalatal airway by pulling the soft palate forward and stabilizing the base of the tongue.
For individuals who have OSA who receive novel OSA treatments (eg, palate expansion, EPAP, oral pressure therapy, tongue stimulation, supine vibration), the evidence includes RCTs, prospective single arm studies, and a meta-analysis of case series. Relevant outcomes are symptoms, functional outcomes, and QOL. The evidence on palate and mandible expansion devices includes a few small series. Further study with well- designed trials is needed to evaluate this treatment. The evidence on nasal EPAP devices in patients with OSA has been reported in prospective case series, an industry-sponsored RCT, and a systematic review that did not include the RCT. The main finding of the RCT was a decrease in the Apnea/Hypopnea Index (AHI), with minor impact on oxygenation, and a decrease in Epworth Sleepiness Scale (ESS) score. One small RCT with 22 patients found no benefit of an oral EPAP therapy device when added to an oral appliance. One comparative trial with historical controls and a retrospective chart review evaluated daytime sleep study (PAP-
500 EXCHANGE STREET, PROVIDENCE, RI 02903-2699 MEDICAL COVERAGE POLICY | 4 (401) 274-4848 WWW.BCBSRI.COM
NAP) to reduce resistance to CPAP titration or use. Additional study is needed to evaluate the efficacy of this intervention. Several RCTs, observational studies, and a meta-analysis have been published with a sleep positioning device that vibrates when the individual is in a supine position. Drop-out rates were high and long-term compliance is unknown. The evidence is insufficient to determine that the technology results in an improvement in the net health outcomes.
CODING
Medicare Advantage Plans and Commercial Products
The oral device is billable under the following HCPCS code(s):
E0485 Oral device/appliance used to reduce upper airway collapsibility, adjustable or non-adjustable,
prefabricated, includes fitting and adjustment
E0486 Oral device/appliance used to reduce upper airway collapsibility, adjustable or non-adjustable,
custom fabricated, includes fitting and adjustment
The following HCPCS code(s) are not covered for Medicare Advantage Plans and not medically necessary for
Commercial Products:
A7049 Expiratory positive airway pressure intranasal resistance valve
E0490 Power source and control electronics unit for oral device/appliance for neuromuscular electrical
stimulation of the tongue muscle, controlled by hardware remote
E0491 Oral device/appliance for neuromuscular electrical stimulation of the tongue muscle, used in
conjunction with the power source and control electronics unit, controlled by hardware remote, 90-
day supply
E0492 Power source and control electronics unit for oral device/appliance for neuromuscular electrical
stimulation of the tongue muscle, controlled by phone application
E0493 Oral device/appliance for neuromuscular electrical stimulation of the tongue muscle, used in
conjunction with the power source and control electronics unit, controlled by phone application, 90-
day supply
E0530 Electronic positional obstructive sleep apnea treatment, with sensor, includes all components and
accessories, any type
The following code(s) can be used for the oral interface used with oral pressure therapy devices and are not
covered for Medicare Advantage Plans and not medically necessary for Commercial Products:
A7047 Oral interface used with respiratory suction pump, each
The above HCPCS code(s) can be used for oral pressure therapy devices such as the Winx system.
CPT or HCPCS code(s) have not been assigned to all of the services or therapies addressed in this policy. Therefore, claims for those services should be filed with the unlisted DME code.
RELATED POLICIES
Durable Medical Equipment
Unlisted Procedures
PUBLISHED Provide Update, November 2025 Provide Update, October 2024 Provider Update, August 2023 Provider Update, June 2022 Provider Update, August 2021
REFERENCES
- Somers VK, White DP, Amin R, et al. Sleep apnea and cardiovascular disease: an American Heart Association/american College Of Cardiology Foundation Scientific Statement from the American Heart Association Council for High Blood Pressure Research Professional Education Committee, Council on Clinical Cardiology, Stroke Council, and Council On Cardiovascular Nursing. In collaboration with the
500 EXCHANGE STREET, PROVIDENCE, RI 02903-2699 MEDICAL COVERAGE POLICY | 5 (401) 274-4848 WWW.BCBSRI.COM
National Heart, Lung, and Blood Institute National Center on Sleep Disorders Research (National Institutes of Health). Circulation. Sep 02 2008; 118(10): 1080-111. PMID 18725495
- Balk EM, Moorthy D, Obadan NO, et al. Diagnosis and Treatment of Obstructive Sleep Apnea in Adults. Comparative Effectiveness Review No. 32 (AHRQ Publication No. 11-EHC052-EF). Rockville, MD: Agency for Healthcare Research and Quality; 2011.
- Kushida CA, Morgenthaler TI, Littner MR, et al. Practice parameters for the treatment of snoring and Obstructive Sleep Apnea with oral appliances: an update for 2005. Sleep. Feb 2006; 29(2): 240-3. PMID 16494092
- McEvoy RD, Antic NA, Heeley E, et al. CPAP for Prevention of Cardiovascular Events in Obstructive Sleep Apnea. N Engl J Med. Sep 08 2016; 375(10): 919-31. PMID 27571048
- Pattipati M, Gudavalli G, Zin M, et al. Continuous Positive Airway Pressure vs Mandibular Advancement Devices in the Treatment of Obstructive Sleep Apnea: An Updated Systematic Review and Meta-Analysis. Cureus. Jan 2022; 14(1): e21759. PMID 35251830
- Ramar K, Dort LC, Katz SG, et al. Clinical Practice Guideline for the Treatment of Obstructive Sleep Apnea and Snoring with Oral Appliance Therapy: An Update for 2015. J Clin Sleep Med. Jul 15 2015;11(7): 773-827. PMID 26094920
- Yu M, Ma Y, Han F, et al. Long-term efficacy of mandibular advancement devices in the treatment of adult obstructive sleep apnea: A systematic review and meta-analysis. PLoS One. 2023; 18(11):e0292832. PMID 38015938
- Liao J, Shi Y, Gao X, et al. Efficacy of Oral Appliance for Mild, Moderate, and Severe Obstructive Sleep Apnea: A Meta-analysis. Otolaryngol Head Neck Surg. May 2024; 170(5): 1270-1279. PMID 38363016
- Johal A, Haria P, Manek S, et al. Ready-Made Versus Custom-Made Mandibular Repositioning Devices in Sleep Apnea: A Randomized Clinical Trial. J Clin Sleep Med. Feb 15 2017; 13(2): 175-182. PMID 27784410
- Bosschieter PFN, Uniken Venema JAM, Vonk PE, et al. Equal effect of a noncustom vs a custom mandibular advancement device in treatment of obstructive sleep apnea. J Clin Sleep Med. Sep 012022; 18(9): 2155-2165. PMID 35532113
- Belkhode V, Godbole S, Nimonkar S, et al. Comparative evaluation of the efficacy of customized maxillary oral appliance with mandibular advancement appliance as a treatment modality for moderate obstructive sleep apnea patients-a randomized controlled trial. Trials. Feb 01 2023; 24(1): 73. PMID36726182
- Abreu AR, Stefanovski D, Patil SP, et al. Neuromuscular electrical stimulation for obstructive sleep apnoea: comparing adherence to active and sham therapy. ERJ Open Res. Nov 2023; 9(6). PMID38152084
- Wessolleck E, Bernd E, Dockter S, et al. Intraoral electrical muscle stimulation in the treatment of snoring. Somnologie (Berl). 2018; 22(Suppl 2): 47-52. PMID 30595662
- Kotecha B, Wong PY, Zhang H, et al. A novel intraoral neuromuscular stimulation device for treating sleep-disordered breathing. Sleep Breath. Dec 2021; 25(4): 2083-2090. PMID 33772397
- Baptista PM, Martínez Ruiz de Apodaca P, Carrasco M, et al. Daytime Neuromuscular Electrical Therapy of Tongue Muscles in Improving Snoring in Individuals with Primary Snoring and Mild Obstructive Sleep Apnea. J Clin Med. Apr 27 2021; 10(9). PMID 33925376
- Nokes B, Schmickl CN, Brena R, et al. The impact of daytime transoral neuromuscular stimulation on upper airway physiology - A mechanistic clinical investigation. Physiol Rep. Jun 2022; 10(12): e15360.PMID 35748091
- Nokes B, Baptista PM, de Apodaca PMR, et al. Transoral awake state neuromuscular electrical stimulation therapy for mild obstructive sleep apnea. Sleep Breath. May 2023; 27(2): 527-534. PMID35624401
- Singh GD, Griffin T, Cress SE. Biomimetic oral appliance therapy in adults with severe obstructive sleep apnea. J Sleep Disord Ther. 2016;5:227.
- Singh GD, Cress SE. Biomimetic oral appliance therapy in adults with mild to moderate obstructive sleep apnea using combined maxillo-mandibular correction. J Sleep Disord Manag. 2017;3(1):014.
- Srijithesh PR, Aghoram R, Goel A, et al. Positional therapy for obstructive sleep apnoea. Cochrane Database Syst Rev. May 01 2019; 5(5): CD010990. PMID 31041813
- Eijsvogel MM, Ubbink R, Dekker J, et al. Sleep position trainer versus tennis ball technique in positional obstructive sleep apnea syndrome. J Clin Sleep Med. Jan 15 2015; 11(2): 139-47. PMID 25515276
- de Ruiter MHT, Benoist LBL, de Vries N, et al. Durability of treatment effects of the Sleep Position Trainer versus oral appliance therapy in positional OSA: 12-month follow-up of a randomized controlled trial. Sleep Breath. May 2018; 22(2): 441-450. PMID 28913630
500 EXCHANGE STREET, PROVIDENCE, RI 02903-2699 MEDICAL COVERAGE POLICY | 6 (401) 274-4848 WWW.BCBSRI.COM
- Berry RB, Uhles ML, Abaluck BK, et al. Night Balance Sleep Position Treatment Device Versus Auto- Adjusting Positive Airway Pressure for Treatment of Positional Obstructive Sleep Apnea. J Clin SleepMed. Jul 15 2019; 15(7): 947-956. PMID 31383231
- van Maanen JP, de Vries N. Long-term effectiveness and compliance of positional therapy with the sleep position trainer in the treatment of positional obstructive sleep apnea syndrome. Sleep. Jul 012014; 37(7): 1209-15. PMID 25061249
- Beyers J, Dieltjens M, Kastoer C, et al. Evaluation of a Trial Period With a Sleep Position Trainer in Patients With Positional Sleep Apnea. J Clin Sleep Med. Apr 15 2018; 14(4): 575-583. PMID 29609712
- Buyse B, Ciordas S, Hoet F, et al. Positional obstructive sleep apnoea: challenging findings inconsecutive patients treated with a vibrating position trainer. Acta Clin Belg. Dec 2019; 74(6): 405-413.PMID 30433857
- American Academy of Otolaryngology-Head and Neck Surgery. Position Statement: Treatment of obstructive sleep apnea. 2021 https://www.entnet.org/resource/position-statement-treatment-of- obstructive-sleep-apnea/ Accessed May 9, 2025.
- Section on Pediatric Pulmonology, Subcommittee on Obstructive Sleep Apnea Syndrome. American Academy of Pediatrics. Clinical practice guideline: diagnosis and management of childhood obstructive sleep apnea syndrome. Pediatrics. Apr 2002; 109(4): 704-12. PMID 11927718
- Marcus CL, Brooks LJ, Draper KA, et al. Diagnosis and management of childhood obstructive sleep apnea syndrome. Pediatrics. Sep 2012; 130(3): 576-84. PMID 22926173
- Epstein LJ, Kristo D, Strollo PJ, et al. Clinical guideline for the evaluation, management and long-term care of obstructive sleep apnea in adults. J Clin Sleep Med. Jun 15 2009; 5(3): 263-76. PMID 19960649
- American Academy of Sleep Medicine (AASM). AASM statement on Zepbound approval. Dec 23, 2024. https://aasm.org/zepbound-approval-sleep-apnea-american-academy-sleep-medicine-statement. Accessed May 2, 2025.
- Yeghiazarians Y, Jneid H, Tietjens JR, et al. Obstructive Sleep Apnea and Cardiovascular Disease: A Scientific Statement From the American Heart Association. Circulation. Jul 20 2021; 144(3): e56-e67.PMID 34148375
- ASMBS Clinical Issues Committee. Peri-operative management of obstructive sleep apnea. Surg Obes Relat Dis. 2012; 8(3): e27-32. PMID 22503595
- Chowdhuri S, Quan SF, Almeida F, et al. An Official American Thoracic Society Research Statement: Impact of Mild Obstructive Sleep Apnea in Adults. Am J Respir Crit Care Med. May 01 2016; 193(9):e37-
- PMID 27128710
- National Institute for Health and Care Excellence (NICE). Obstructive sleep apnoea/hypopnea syndrome and obesity hypoventilation syndrome in over 16s: NG202. Published August 20, 2021;https://www.nice.org.uk/guidance/ng202/chapter/1-Obstructive-sleep-apnoeahypopnoea- syndrome#treatments-for-mild-osahs. Accessed May 3, 2025.
- National Institute for Health and Care Excellence (NICE). Daytime intraoral neuromuscular electrical tongue stimulation using a removable device for obstructive sleep apnoea [IPG760]. April 19, 2023.https://www.nice.org.uk/guidance/ipg760/resources/daytime-intraoral-neuromuscular-electrical- tongue-stimulation-using-a-removable-device-for-obstructive-sleep-apnoea-pdf-1899876394571461. Accessed May 2, 2025.
- The Department of Veteran's Affairs and the Department of Defense (VA/DOD). VA/DOD Clinical Practice Guideline For The Management Of Chronic Insomnia Disorder And Obstructive Sleep Apnea. January,
- https://www.healthquality.va.gov/guidelines/CD/insomnia/I-OSA-CPG_2025- Guildelinefinal20250422.pdf. Accessed May 2, 2025.
Pattipati M, Gudavalli G, Zin M, et al. Continuous Positive Airway Pressure vs Mandibular Advancement Devices in the Treatment of Obstructive Sleep Apnea: An Updated Systematic Review and Meta-Analysis. Cureus. Jan 2022; 14(1): e21759. PMID 35251830
i
500 EXCHANGE STREET, PROVIDENCE, RI 02903-2699 MEDICAL COVERAGE POLICY | 7 (401) 274-4848 WWW.BCBSRI.COM
This medical policy is made available to you for informational purposes only. It is not a guarantee of payment or a substitute for your medical judgment in the treatment of your patients. Benefits and eligibility are determined by the member's subscriber agreement or member certificate and/or the employer agreement, and those documents will supersede the provisions of this medical policy. For information on member-specific benefits, call the provider call center. If you provide services to a member which are determined to not be medically necessary (or in some cases medically necessary services which are non-covered benefits), you may not charge the member for the services unless you have informed the member and they have agreed in writing in advance to continue with the treatment at their own expense. Please refer to your participation agreement(s) for the applicable provisions. This policy is current at the time of publication; however, medical practices, technology, and knowledge are constantly changing. BCBSRI reserves the right to review and revise this policy for any reason and at any time, with or without notice. Blue Cross & Blue Shield of Rhode Island is an independent licensee of the Blue Cross and Blue Shield Association. CLICK THE ENVELOPE ICON BELOW TO SUBMIT COMMENTS