Humana Urinary Bladder Dysfunction - Medicare Advantage Form
YesNoN/A
YesNoN/A
Please refer to CMS website for the most current applicable National Coverage Determination (NCD)/
Local Coverage Determination (LCD)/Local Coverage Article (LCA)/CMS Online Manual
System/Transmittals.
Urinary Bladder Dysfunction
Page: 2 of 34
Jurisdiction
Medicare
Administrative
Contractors
(MACs)
Applicable
States/Territories
Type
Title
ID Number
NCD
NCD
NCD
NCD
NCD
NCD
NCD
Biofeedback Therapy for the
Treatment of Urinary
Incontinence for the treatment
Bladder Stimulators
(Pacemakers)
Incontinence Control Devices
Non-Implantable Pelvic Floor
Electrical Stimulator
Sacral Nerve Stimulation for
Urinary Incontinence
Uroflowmetric Evaluations
Durable Medical Equipment
(DME) Reference List
30.1.1
230.16
230.10
230.8
230.18
230.2
280.1
LCD
Urological Supplies
L33803
All States
JB, JH – CGS
Administrators,
LLC (DME MAC)
JA, JD – Noridian
Healthcare
Solutions, LLC
(DME MAC)
J6 - National
Government
Services, Inc.
(Part A/B MAC)
IL, MN, WI
LCA
LCD
LCD
Billing and Coding: Posterior
Tibial Nerve Stimulation for
Voiding Dysfunction
Posterior Tibial Nerve
Stimulation for Voiding
Dysfunction
Urodynamics
A57453
L33396
L33576
Urinary Bladder Dysfunction
Page: 3 of 34
Billing and Coding: Sacral Nerve
Stimulation for Urinary and
Fecal Incontinence
A55835
Post-Void Residual Urine
and/or Bladder Capacity by
Ultrasound
L34085
J15 - CGS
Administrators,
LLC (Part A/B
MAC)
KY, OH
Urodynamics
Billing and Coding: Sacral Nerve
Stimulation for Urinary and
Fecal Incontinence
Billing and Coding: Sacral Nerve
Stimulation for Urinary and
Fecal Incontinence
Billing and Coding: Urodynamic
Services - Non-invasive
Billing and Coding: Posterior
Tibial Nerve Stimulation for
Voiding Dysfunction
Posterior Tibial Nerve
Stimulation for Voiding
Dysfunction
L34056
A53359
A53017
A58543
A57453
L33396
L33576
JE - Noridian
Healthcare
Solutions, LLC
JF - Noridian
Healthcare
Solutions, LLC
JN - First Coast
Service Options,
Inc. (Part A/B
MAC)
CA, HI, NV,
American Samoa,
Guam, Northern
Mariana Islands
AK, AZ, ID, MT,
ND, OR, SD, UT,
WA, WY
FL, PR, VI
JK - National
Government
Services, Inc.
(Part A/B MAC
CT, MA, ME, NY,
NH, RI, VT
LCA
LCD
LCD
LCA
LCA
LCA
LCA
LCD
LCD
Urinary Bladder Dysfunction
Page: 4 of 34
Urodynamics
Description
Urinary bladder dysfunction is a broad term that may encompass many lower urinary tract symptoms such
as incontinence, overactive bladder and retention.
Urinary incontinence (UI) is the involuntary leakage of urine, which may be caused by aging, disease,
postsurgical complications, trauma or other conditions.
• Stress urinary incontinence (SUI) is the involuntary loss of urine without a bladder contraction which
occurs when the muscles and tissues around the bladder (eg, pelvic floor, sphincter) become weak or do
not work. Urine may leak when there is pressure exerted on the bladder through actions such as
coughing or sneezing.
• Urge urinary incontinence (UUI) is the involuntary loss of urine associated with a bladder contraction. It
is a sudden, overwhelming urge to urinate due to involuntary contractions of the muscular wall of the
bladder, which may cause an unintentional loss of urine. Frequent urination, including nocturia (awaken
at night to urinate), can also occur.
Mixed incontinence may present with symptoms of both stress and urge incontinence.
Overflow incontinence occurs when the bladder does not empty, causing leakage if it becomes overly full.
Overactive bladder (OAB) is characterized as urgency, frequency and nocturia, with or without urge
incontinence.
Urinary retention (UR) is the incomplete emptying of the bladder or cessation of urination. It may be acute
or chronic in nature. The problem is considered chronic when there has been a postvoid residual (PVR)
volume greater than 300 mL measured on 2 separate occasions and persisting for at least 6 months.85 Some
causes for chronic urinary retention (CUR) may include bladder outlet obstruction (related to urethral
strictures following a surgery or injury), detrusor-sphincter dyssynergia (lack of coordination between
bladder contraction and sphincter relaxation), impaired bladder contractility (underactive bladder [UAB]
often related to neurologic conditions [neurogenic lower urinary tract dysfunction]) or a combination of
factors.
Evaluation
Urinary Bladder Dysfunction
Page: 5 of 34
Treatment for UI or OAB depends on the type of incontinence and the underlying cause; therefore, prior to
treatment, an evaluation must be performed. The initial assessment includes gathering the individual’s
history, conducting a physical exam, performing a cough stress test, measuring postvoid residual volume
(PVR) and completing a urinalysis. Additional tests (eg, cystoscopy, urodynamic testing) may be necessary if
surgical intervention is being considered.
Vaginal tactile imaging (or biomechanical transvaginal mapping) is a type of assessment which provides
high resolution mapping of pressures and assesses the strength of the pelvic floor muscles within the
vagina. A physician or surgeon can view this real-time data to potentially assist with evaluations.
Diagnosis for UR most often involves the measurement of PVR volumes which are obtained by
catheterization or by bladder ultrasonography showing an elevated residual urine volume. Other tests (eg,
blood tests, cystography, cystoscopy, ultrasonography, urinalysis, urodynamic testing) may be performed
based on clinical findings.
The penile cuff test (eg, UroCuff) is a noninvasive method to measure urinary pressure flow in an individual
with lower urinary tract symptoms (LUTS). A small inflatable cuff is placed around the penile shaft and
inflated during urination. As the cuff is deflated, a surge in urine flow returns followed by a steady urine
flow. Bladder function is determined from interruption pressure versus flow rate. The maximum pressure
for cuff interruption of urinary flow is plotted to reportedly diagnose bladder outlet obstruction (BOO) or
benign prostatic hyperplasia (BPH).
Treatments
Examples of UI/OAB or UR treatments include, but may not be limited to:
Artificial urinary sphincter involves the implantation of an artificial valve in the genitourinary tract to
restore continence.
Behavioral training provides education regarding exercises, muscle control and relaxation techniques to
control incontinence.
Biofeedback is a training technique that uses an external sensor to indicate bodily processes and teaches
the individual to contract the urinary sphincter in response to the urge to urinate, which may help
strengthen the sphincter.
Bladder support surgeries are performed using a variety of open or laparoscopic techniques to help restore
continence. Examples include, but may not be limited to:
• Procedures to secure the bladder neck using sutures (eg, Burch colposuspension, open or laparoscopic)
are performed to help obtain normal bladder neck position
• Suburethral or urethral bulb mesh placement (also referred to as a sling procedure) is more commonly
performed and involves the use of synthetic (eg, single incision sling [SIS], tension-free vaginal tape
[TVT], transobturator tape [TOT]) and nonsynthetic materials to aid in the support of the urethral
Urinary Bladder Dysfunction
Page: 6 of 34
sphincter. These devices are placed to support the urethra and the bladder neck to prevent downward
rotation of these structures.
• Sling procedures are also sometimes performed on an individual without incontinence during pelvic
organ prolapse repairs to decrease the risk of postoperative SUI.
Bladder training is a method that includes timed voiding, keeping a diary and gradually increasing the time
between voids so an individual can learn to manage UI.
Catheterization is a method used to drain the bladder. A urinary catheter may be in-dwelling (left in place
for a specific amount of time) or be utilized intermittently to remove urine.
Correction, reduction and/or removal of an anatomic obstruction related to the cause of urinary retention
may be necessary. There are a variety of procedure types depending on the nature of the obstruction
including, but may not be limited to: mass removal, repair of pelvic organ prolapse, repair of urethral
stricture, transvaginal sling excision, urethral dilation, urethral reconstruction, urinary diversion and
treatment of benign prostatic hyperplasia (BPH).
Cryogen-cooled radiofrequency remodeling (eg, Viveve) is a method proposed to reduce stress urinary
incontinence by delivering radiofrequency (RF) energy to vaginal tissues around the urethra to improve
structural integrity and increase urethra support. (Refer to Coverage Limitations section)
Enuresis (bed wetting) alarms are devices that sense urine and set off an alarm so that an individual can
wake up to use the toilet.
External urinary catheters or collection devices are noninvasive products to purportedly manage urinary
incontinence and prevent catheter associated urinary tract infections. There are two basic types, disposable
and non-disposable. The PureWick Urinary Collection System and PrimaFit External Urinary System utilize
suction and a soft, flexible wicking material to draw urine away from the body and into a sealed collection
cannister; the wicking material is disposable and needs to be replaced often. The TrueClr device acts similar
to a meatal cup but utilizes a rubber sleeve that stays in place and draws urine out with light suction; the
sleeve is reusable, being cleaned with soap and water.
Extracorporeal magnetic innervation (ExMI) (eg, NeoControl Pelvic Floor Therapy System) utilizes magnetic
fields to stimulate the nerves of the pelvic floor or the sacral nerve roots which purportedly results in the
contraction of the pelvic muscles.
Indwelling intraurethral valve drainage prosthesis (eg, inFlow Voiding Prosthesis) is a device that is
designed for use in a female with impaired detrusor contractility (IDC). An individual diagnosed with IDC
cannot spontaneously urinate due to insufficient bladder muscle contractions, which can be caused by
conditions including multiple sclerosis, spinal cord injury or stroke. The prosthesis is initially inserted by a
physician; it gets replaced at least every 29 days. To use the device, the individual sits on the toilet, holds
the activator over the lower pelvic area and presses the button which opens the valve and activates the
pump. This purportedly empties the bladder, while releasing the button closes the valve and stops the flow
of urine.51
Urinary Bladder Dysfunction
Page: 7 of 34
Nonimplanted pelvic floor electrical stimulation (eg, Detrusan, UROSTYM) are rehabilitative devices that
deliver small amounts of electrical stimulation to the nerves and muscles of the pelvic floor and bladder via
a probe that is placed in the vagina, transurethral catheter or via surface electrodes. Some systems also
provide visual biofeedback. The goal is that the electrical stimulation will strengthen muscles and retrain
the bladder. These systems are utilized in clinic-based settings.
Pelvic floor exercises (eg, Kegel exercises, pelvic muscle rehabilitation) are a daily training program for the
muscles that support the uterus, bladder and other pelvic organs to strengthen pelvic muscles to prevent
accidental urine leakage. There are a variety of nonimplanted pelvic muscle stimulation devices being
marketed and made available over the counter (OTC) for home use which either provide vibrations, motion
sensing or electrical prompting (eg, Apex, Attain, Flyte, INNOVO, leva Pelvic Health System).
Percutaneous tibial nerve stimulation (PTNS) involves stimulation of the tibial nerve which travels to the
sacral nerve plexus. This is believed to lead to improvements in voiding function, urgency and control. Two
methods have been introduced for this type of stimulation; however, one is still in the initial stages of
development.
• Implanted PTNS (eg, eCoin, Protect PNS, RENOVA iStim, StimRouter PNS) is being explored as an option
for those with OAB and associated symptoms. The two approaches for this technology include
implanting a lead through a small surgical incision or injecting a lead through an ultrasound-guided
delivery system. An external device or electrode is then worn around the ankle during treatment and the
physician will set the stimulation parameters in advance so that the individual can conduct treatments at
home in 30-minute sessions each day.
• Nonimplanted PTNS (eg, NURO System, Urgent PC) is a minimally invasive technique, fine-needle
electrodes are placed externally near the tibial nerve above the ankle. The electrode then carries
electrical impulses from a stimulator to the sacral nerve plexus. This typically involves one 30-minute
session per week, for 10-12 weeks, occurring in a clinical setting.44
Periurethral bulking agents (eg, Bulkamid, Coaptite, Durasphere EXP, Macroplastique) is a procedure that
involves the injection of collagen or other substances into the vicinity of the urinary sphincter which
increases the tissue bulk, thereby increasing pressure in the urethra to maintain continence.
Sacral nerve stimulation (SNS) (eg, Axonics SNM System, InterStim II, InterStim Micro, InterStimX) is a
procedure which involves the implantation of electrodes near the sacral nerve to control the function of the
muscles required for urination.
Stem cell transplantation is being proposed as a possible treatment for SUI. Examples of stem cells under
investigation include bone marrow-derived, mesenchymal, muscle-derived cells and umbilical cord blood
cells.
Transperineal implantation of permanent adjustable balloon continence device (eg, ProACT Therapy, ACT
Therapy) consists of adjustable balloon implants that are placed via a perineal approach. The fluid filled
balloons reportedly provide pressure and support at the bladder neck to prevent bladder leakage. Titanium
ports attached via tubing to each balloon are placed in the scrotum, which allows for postoperative volume
Urinary Bladder Dysfunction
Page: 8 of 34
adjustment. This device is indicated for adult men who have stress urinary incontinence arising from
intrinsic sphincter deficiency of at least 12 months duration following radical prostatectomy or
transurethral resection of the prostate (TURP) and who have failed to respond adequately to conservative
therapy. ACT Therapy, for use in women, is not yet available in the United States.
Transurethral radiofrequency ablation (eg, Renessa procedure) utilizes controlled heat that is applied from
a radiofrequency device to supposedly denature the collagen in the tissues of the lower urinary tract. After
healing, the tissue is reportedly firmer which increases resistance to involuntary leakage.
Urethral excision involves the surgical removal of a urethral diverticulum or urogenital fistula. A urethral
diverticulum is a localized outpouching which forms next to the urethra. A urogenital fistula tract is an
abnormal connection between the genital tract and bladder, urethra or ureters. Both conditions may lead
to urinary incontinence.
Vaginal laser therapy (eg, FemTouch, IncontiLase) has been proposed as a minimally invasive treatment for
SUI as well as pelvic organ prolapse (POP). The two types of lasers currently being studied are Er:YAG and
CO2. The controlled heat from the lasers reportedly causes reconstruction and remodeling of the collagen;
thereby, providing support to the pelvic floor structures.43
Vaginal pessaries are rigid, intravaginal devices that support the bladder neck where the urethra joins the
bladder to reduce incontinence. Urethral inserts (eg, Contino) similar support for males by obstructing the
flow of urine from exiting the body.
Coverage Determination
Humana follows the CMS requirement that only allows coverage and payment for services that are
reasonable and necessary for the diagnosis or treatment of illness or injury or to improve the functioning of
a malformed body member except as specifically allowed by Medicare.
In interpreting or supplementing the criteria above and in order to determine medical necessity consistently,
Humana may consider the following criteria:
URINARY INCONTINENCE (UI) AND OVERACTIVE BLADDER (OAB)
UI/OAB Evaluation
Diagnostic evaluation for urinary incontinence (UI/OAB) will be considered medically reasonable and
necessary when the following requirements are met:
Initial diagnostic evaluation for UI/OAB includes the following:
• History and physical exam; AND
• Measurement of postvoid residual volume (PVR) to exclude retention23; AND
Urinary Bladder Dysfunction
Page: 9 of 34
• Urinalysis ruling out hematuria or urinary tract infection7,34; AND
• Positive cough stress test (during physical examination, cystometry or urodynamics) to identify stress
urinary incontinence (not necessary for a suspected diagnosis of UUI/OAB)
After initial diagnostic evaluation above has been performed, urodynamic testing for UI/OAB may be
performed for the following indications24,25,33:
• As consideration for surgical intervention, particularly if there has been a previous failed surgery for the
issue or the individual is considered a high-surgical risk; OR
• Etiology of incontinence is unclear; OR
• Incontinence refractory to conservative management; OR
• Presence of other comorbid conditions which include, but may not be limited to:
o Abnormal post-void-residual urinalysis; OR
o History of previous incontinence surgery; OR
o Neurologic condition affecting voiding (eg, multiple sclerosis, spinal cord lesions/injury); OR
o Persistent symptoms of difficult bladder emptying; OR
o Previous pelvic surgery or prostatectomy; OR
o Prostate nodule (eg, asymmetry, other suspicion of prostate cancer); OR
o Recurrent symptomatic urinary tract infection
After initial diagnostic evaluation above has been performed, cystoscopy for UI/OAB may be performed for
the following indications24,25,33:
• Acute onset incontinence; OR
• Incontinence refractory to conservative management; OR
• Presence of microscopic hematuria; OR
• Recurrent urinary tract infection; OR
• Suspicion of bladder neck contracture, foreign body or urethral stricture after a previous surgery (eg,
gynecologic surgery, prostatectomy)7
Stress Urinary Incontinence (SUI) Treatments
The treatments listed below for SUI will be considered medically reasonable and necessary when the
following requirements are met:
• Artificial urinary sphincter implantation; OR
• Bladder support surgeries (eg, Burch colposuspension [laparoscopic or open], suburethral or urethral
bulb mesh placement [sling procedure]*) using a US Food & Drug Administration (FDA) approved device;
OR
Urinary Bladder Dysfunction
Page: 10 of 34
• Periurethral bulking agents (eg, Bulkamid, Coaptite, Durasphere EXP, Macroplastique);
AND all the following:
• Diagnostic evaluation has confirmed a diagnosis of SUI; AND
• Failure of or contraindication to conservative management
Suburethral Mesh Placement or Urethral Excision for Other Diagnoses
The procedures listed below (without failure of conservative management) will be considered medically
reasonable and necessary when the following requirements are met:
• Urethral excision when a urethral diverticulum or urogenital tract fistula is present and causing urinary
incontinence; OR
• Suburethral mesh placement (sling procedures)* using an FDA-approved device AND either of the
following:
o Pelvic organ prolapse without urinary incontinence; OR
o Performed in conjunction with pelvic organ prolapse surgery (eg, anterior colporrhaphy [cystocele
repair], posterior colporrhaphy [rectocele repair])
*Per the American Urological Association (AUA), intraoperative cystoscopy should be performed during all
synthetic sling procedures to identify urinary tract injury.15
Urge Urinary Incontinence (UUI)/Overactive Bladder (OAB) Treatments
The treatments listed below for UUI/OAB will be considered medically reasonable and necessary when all
the following requirements are met:
• Nonimplanted PTNS (eg, NURO System, Urgent PC) when the following criteria are met17,22:
o Absence of contraindications; AND
o Diagnostic evaluation confirms a diagnosis of UUI/OAB; AND
o Failure of or contraindication conservative management; AND
o If the above criteria are met:
A total of 12 treatments (1 per week) will be initially approved
If there is a 50% decrease in symptoms as evidenced by a daily urolog (record of bladder events,
voiding diary), an additional 9 months of treatment (1 per month) may be approved subject to
continued improvement; OR
Urinary Bladder Dysfunction
Page: 11 of 34
• Sacral nerve stimulation (SNS) (eg, Axonics SNM System, InterStim II, InterStim Micro, InterStim X) with
an FDA-approved device when all the following criteria are met 18,19,20,32:
o Absence of contraindications; AND
o Diagnostic evaluation confirms a diagnosis of UUI/OAB; AND
o Failure of or contraindication to conservative management; AND
o Permanent implantation of a SNS requires a prior trial test stimulation for a minimum of 2 days that
demonstrates a documented 50% or greater improvement in incontinence symptoms
Removal of an SNS device will be considered medically reasonable and necessary when a previously
implanted device and/or its associated components cause complications or unintended negative outcomes
(eg, adverse change in voiding function, infection, new pain, undesirable stimulation) for the individual.
Replacement of an SNS device using an FDA-approved device will be considered medically reasonable and
necessary when all the following requirements are met:
• Previously implanted device and/or associated components are no longer functioning appropriately (eg,
defective pulse generator, lead migration) and are no longer under warranty; AND
• Absence of contraindications
CHRONIC URINARY RETENTION (CUR)
Chronic Urinary Retention Evaluation
Diagnostic evaluation for CUR will be considered medically reasonable and necessary when all the
following requirements are met:
Initial diagnostic evaluation for CUR includes the following:
• History and physical exam; AND
• Measurement of PVR by catheterization and/or bladder ultrasound (PVR greater than 200 mL is
abnormal and PVR between 100 mL to 200 mL warrant clinical correlation23,88); AND
• Urinalysis ruling out hematuria or urinary tract infection7,34
Urinary Bladder Dysfunction
Page: 12 of 34
After initial diagnostic evaluation above has been performed, cystoscopy, cystourethroscopy,
electromyography (EMG), penile cuff test or other urodynamic testing for CUR may be performed for the
following indications 21,24,25,33:
• As consideration for urological surgical intervention, particularly if there has been a previous failed
surgery for the issue or the individual is considered a high-surgical risk; OR
• CUR refractory to conservative management; OR
• Presence of other comorbid conditions which include, but may not be limited to:
o Abnormal post-void-residual urinalysis; OR
o History of previous incontinence surgery; OR
o Neurologic condition affecting voiding (eg, multiple sclerosis, spinal cord lesions/injury); OR
o Persistent symptoms of difficult bladder emptying; OR
o Previous pelvic surgery or prostatectomy; OR
o Prostate nodule (eg, asymmetry, other suspicion of prostate cancer); OR
o Recurrent symptomatic urinary tract infection
Chronic Urinary Retention Treatments
The following treatments for CUR will be considered medically reasonable and necessary when all the
following requirements are met:
• Correction, reduction and/or removal of an anatomic obstruction (eg, mass removal, repair of pelvic
organ prolapse, repair of urethral strictures, transvaginal sling excision, urethral dilation, urethral
reconstruction, urinary diversion, treatment of benign prostatic hyperplasia [BPH]); OR
• Indwelling intraurethral valve drainage prosthesis and replacement accessories (eg, inFlow Voiding
Prosthesis) for those with urinary retention due to impaired detrusor contractility (IDC)27; OR
• Sacral nerve stimulation (SNS) (eg, Axonics SNM System, InterStim II, InterStim Micro, InterStim X) with
an FDA-approved device when all the following criteria are met18,19,20,32:
o Absence of contraindications; AND
o Diagnostic evaluation confirms a diagnosis of nonobstructive CUR; AND
o Failure of or contraindication to conservative management
o Permanent implantation of an SNS requires a prior trial test stimulation for a minimum of 2 days that
demonstrates a documented 50% decrease in residual urine volume
Urinary Bladder Dysfunction
Page: 13 of 34
Removal of an SNS device will be considered medically reasonable and necessary when a previously
implanted device and/or its associated components cause complications or unintended negative outcomes
(eg, adverse change in voiding function, infection, new pain, undesirable stimulation) for the individual.
Replacement of an SNS device will be considered medically reasonable and necessary when all the
following requirements are met:
• Previously implanted device and/or its associated components are no longer functioning appropriately
(eg, defective pulse generator, lead migration) and are no longer under warranty; AND
• Absence of contraindications; AND
• FDA-approved device is being utilized as the replacement
The use of the criteria in this Medicare Advantage Medical Coverage Policy provides clinical benefits highly
likely to outweigh any clinical harms. Services that do not meet the criteria above are not medically
necessary and thus do not provide a clinical benefit. Medically unnecessary services carry risks of adverse
outcomes and may interfere with the pursuit of other treatments which have demonstrated efficacy.
Coverage Limitations
US Government Publishing Office. Electronic code of federal regulations: part 411 – 42 CFR § 411.15 -
Particular services excluded from coverage
Urinary Incontinence (UI)/Overactive Bladder (OAB)
The following UI/OAB treatments will not be considered medically reasonable and necessary:
• Cryogen-cooled radiofrequency remodeling (eg, Viveve); OR
• Extracorporeal magnetic innervation (ExMI) (eg, NeoControl Pelvic Floor Therapy System); OR
• Implanted PTNS (eg, eCoin, Protect PNS, RENOVA iStim, StimRouter PNS); OR
• Vaginal laser therapy (eg, FemTouch, IncontiLase); OR
• Nonimplanted PTNS (eg, NURO System, Urgent PC) if any of the following contraindications are present:
o Individual prone to excessive bleeding; OR
o Individual with pacemaker or implantable defibrillator; OR
o Neurogenic lower urinary tract dysfunction (NLUTD) (eg, diabetic neuropathy, multiple sclerosis,
spinal cord injury); OR
o Pregnancy or plan to become pregnant while using the device; OR
• SNS (eg, Axonics SNM System, InterStim II, InterStim Micro, InterStimX) if any of the following
Urinary Bladder Dysfunction
Page: 14 of 34
contraindications are present 18,19,20,32:
o Permanent bilateral stimulation; OR
o Bladder capacity less than 100 ml; OR
o Individual not capable of operating the device; OR
o Mechanical obstruction present (eg, benign prostatic hyperplasia, cancer, urethral stricture); OR
o Neurogenic lower urinary tract dysfunction (NLUTD) (eg, diabetic neuropathy, multiple sclerosis,
spinal cord injury); OR
o Pregnancy or plan to become pregnant while using the device; OR
• Transperineal implantation of permanent adjustable balloon continence device (eg, ProACT system, ACT
system); OR
• Transurethral radiofrequency ablation (eg, Renessa procedure)
A review of the current medical literature shows that the evidence is insufficient to determine that these
services (or for an individual with any of the above contraindications) are standard medical treatments.
There remains an absence of randomized, blinded clinical studies examining benefit and long-term clinical
outcomes establishing the value of these services in clinical management.
Summary of Evidence
Cryogen-cooled Radiofrequency Remodeling
Published evidence evaluating the Viveve System for treating SUI is limited to 6-month and 12-month
follow-up studies of a small feasibility study evaluating 1 or 2 treatment sessions with the Viveve System in
37 women with SUI. Clinically meaningful reductions in urinary leakage volume and SUI symptoms were
demonstrated, with no significant differences between 1 or 2 Viveve treatments. Additional published
evidence from the larger randomized PURSUIT trial is needed to characterize the magnitude and duration
of benefit of the Viveve System in reducing SUI symptoms.51
Extracorporeal Magnetic Innervation (ExMI)
There is evidence from controlled and uncontrolled studies that extracorporeal magnetic stimulation can
safely reduce the frequency of incontinence episodes and improve quality of life for women with
UI. However, the effect was short lived and some studies failed to find an effect of EMS. Limitations of the
studies included small sample size, no sham control group, and lack of long-term follow-up.66
Implanted PTNS
Urinary Bladder Dysfunction
Page: 15 of 34
Evidence from 3 pre-post treatment studies is at too high a risk of bias to determine eCoin's safety and
effectiveness for treating UUI. Studies report that eCoin reduced UUI episodes and improved symptoms in
most individuals up to 12-month follow-up; however, findings need validation in multicenter randomized
controlled trials that report long-term (greater than 5 years) individual outcomes. Studies report mild or
moderate device-related adverse events in up to 15% of patients. The existing studies are at substantial risk
of bias from small sample size and lack of concurrent controls and randomization. Also, findings may not
fully generalize across studies because authors used different measures to assess the same outcomes.37
Vaginal Laser Therapy
Limited evidence suggests laser therapy may work for some women with SUI or cystoceles. However, the
safety and effectiveness of laser therapy has not been assessed in controlled trials, so determining how it
compares with other treatments for SUI or cystoceles is not possible. Multicenter, randomized controlled
trials with sufficient sample size and at least a 2-year follow-up are needed to establish the safety and
effectiveness of this minimally invasive treatment. In 2018, the FDA issued a Safety Communication warning
individuals and healthcare providers of problems involving procedures that use energy-based devices for
treating vaginal conditions and symptoms (eg, urinary incontinence, menopause, sexual function).43
Transperineal Implantation of Permanent Adjustable Balloon Continence Device
The body of evidence identified for the ProACT device for treatment of post-prostate surgery UI lacks
controlled studies to determine if the ProACT device is similar, better, or worse than other available
treatments with respect to patient outcomes. Single-arm studies consistently reported improvements from
baseline in some key clinical outcomes. Other outcomes were assessed by too few studies or assessed
inconsistently across studies, precluding firm conclusions. Available evidence regarding potential harms
suggests that the ProACT device may be associated with a moderate risk of complications, including revision
and explantation; however, there is insufficient evidence to determine the relative safety of the ProACT
device compared with other available treatments.60
Transurethral Radiofrequency Ablation
There is some evidence suggesting that transurethral RF energy-therapy is beneficial for carefully selected
patients with refractory symptoms due to SUI and that most patients are satisfied with the treatment.
Despite these positive findings, the strength of the existing data is weakened by flaws in study design and
execution, particularly the loss of high numbers of patients to follow up, and the lack of controls in some
studies. Although no serious adverse events were reported, minor complications occurred such as dysuria,
urinary retention, and urinary tract infection. Additional independent studies are required to establish the
long-term safety and efficacy of this technology since the manufacturer sponsored the existing studies.62
Vaginal tactile imaging (biomechanical transvaginal mapping) will not be considered medically reasonable
and necessary. A review of the current medical literature shows that the evidence is insufficient to
determine that this service is standard medical treatment. There remains an absence of randomized,
blinded clinical studies examining benefit and long-term clinical outcomes establishing the value of this
service in clinical management.
Summary of Evidence
Urinary Bladder Dysfunction
Page: 16 of 34
Vaginal Tactile Imaging (VTI)
VTI may provide biomechanical data which can be applied for computer simulation of surgical procedures
for treatment effectiveness or custom pessary design, however it is important to note that the VTI is not
intended as a diagnostic device. It is not intended to be used to diagnose any specific diseased conditions,
such as pelvic organ prolapse or UI. Image interpretation must be completed by a clinician and is subjective,
utilizing their knowledge of general and functional pelvic anatomy and or clinical experience. There have
not been many conclusive findings in studies.
The following UI devices will not be considered medically reasonable and necessary:
• Enuresis (bed wetting) alarms; OR
• External urinary catheters or collection devices (eg, PrimaFit External Urinary System, PureWick Urine
Collection System, TrueClr)
Although they may be prescribed by a health care practitioner, these UI devices are not covered by
Medicare as they are disposable and/or do not meet the CMS definition of Durable Medical Equipment
(DME).
Chronic Urinary Retention (CUR)
SNS (eg, Axonics SNM System, InterStim II, InterStim Micro, InterStimX) for CUR will not be considered
medically reasonable and necessary if the following contraindications are present 18,19,20,33:
• Permanent bilateral stimulation; OR
• Bladder capacity less than 100 ml; OR
•
Individual not capable of operating the device; OR
• Mechanical obstruction present (eg, benign prostatic hyperplasia [BPH], cancer, urethral stricture); OR
• Neurogenic lower urinary tract dysfunction (NLUTD) (eg, diabetic neuropathy, multiple sclerosis, spinal
cord injury); OR
• Pregnancy or plan to become pregnant while using the device
A review of the current medical literature shows that the evidence is insufficient to determine that this
service is standard medical treatment for an individual with any of the above contraindications. There
remains an absence of randomized blinded clinical studies examining benefit and long-term clinical
outcomes establishing the value of this service in clinical management for these indications.