Three Automations Providers and DMEs can build with ChatGPT and Claude today

Cigna Autonomic Nerve Function Testing - (0506) Form


Autonomic Sudomotor Function Tests (Sweat Testing)

Notes: Testing using portable, automated device (e.g., ANX 3.0™ [ANSAR], VitalScan ANS) is considered experimental and not covered.

Indications

(611515) Is the patient being evaluated for distal small fiber neuropathy? 
(611516) Is the patient being evaluated for reflex sympathetic dystrophy? 
(611517) Does the patient experience recurrent, unexplained syncope? 
(611518) Is the patient diagnosed with a progressive autonomic neuropathy such as diabetic autonomic neuropathy, amyloid neuropathy, Sjogren’s syndrome, idiopathic neuropathy, pure autonomic failure, or multiple system atrophy (Shy-Drager syndrome)? 

Cardiovagal Innervation Testing

Indications

(611519) Is the patient presenting cardiac indications that suggest autonomic nerve dysfunction? 

YesNoN/A
YesNoN/A

Sign up to see the rest of the questions

Unlock the remaining questions and the full coverage workflow.

Sign up for free
Effective Date

NA

Last Reviewed

NA

Original Document

  Reference



The following Coverage Policy applies to health benefit plans administered by Cigna Companies. Certain Cigna Companies and/or lines of business only provide utilization review services to clients and do not make coverage determinations. References to standard benefit plan language and coverage determinations do not apply to those clients. Coverage Policies are intended to provide guidance in interpreting certain standard benefit plans administered by Cigna Companies. Please note, the terms of a customer’s particular benefit plan document [Group Service Agreement, Evidence of Coverage, Certificate of Coverage, Summary Plan Description (SPD) or similar plan document] may differ significantly from the standard benefit plans upon which these Coverage Policies are based. For example, a customer’s benefit plan document may contain a specific exclusion related to a topic addressed in a Coverage Policy. In the event of a conflict, a customer’s benefit plan document always supersedes the information in the Coverage Policies. In the absence of a controlling federal or state coverage mandate, benefits are ultimately determined by the terms of the applicable benefit plan document. Coverage determinations in each specific instance require consideration of 1) the terms of the applicable benefit plan document in effect on the date of service; 2) any applicable laws/regulations; 3) any relevant collateral source materials including Coverage Policies and; 4) the specific facts of the particular situation. Each coverage request should be reviewed on its own merits. Medical directors are expected to exercise clinical judgment and have discretion in making individual coverage determinations. Coverage Policies relate exclusively to the administration of health benefit plans. Coverage Policies are not recommendations for treatment and should never be used as treatment guidelines. In certain markets, delegated vendor guidelines may be used to support medical necessity and other coverage determinations. This Coverage Policy addresses autonomic nerve function testing, including sudomotor, cardiovagal, and adrenergic tests. Coverage Policy Autonomic nerve function testing is considered medically necessary to evaluate autonomic nerve function and aid in the diagnosis of ANY of the following conditions: Distal small fiber neuropathy • Postural tachycardia syndrome • Reflex sympathetic dystrophy (e.g., sympathetically maintained pain, causalgia) • Recurrent, unexplained syncope • Any of the following progressive autonomic neuropathies:  Diabetic autonomic neuropathy  Amyloid neuropathy  Sjogren’s syndrome Medical Coverage Policy: 0506  Idiopathic neuropathy  Pure autonomic failure  Multiple system atrophy (Shy-Drager syndrome) Autonomic nerve function testing to aid in the diagnosis of ANY other condition is considered experimental, investigational or unproven. Autonomic nerve function testing using a portable, automated device (e.g., ANX 3.0™ [Autonomic Nervous System and Respiration (ANSAR)]; VitalScan ANS) for any indication is considered experimental, investigational or unproven. General Background The autonomic nervous system controls the internal organs of the body regulating and maintaining physiologic processes such as blood pressure, heart rate, body temperature, metabolism, sweating, urination, and fluid and electrolyte balance. The autonomic nervous system is controlled by two nerve systems, the parasympathetic nervous system and sympathetic nervous system. Stimulus to the sympathetic nervous system activates what is commonly referred to as the “fight or flight response”, involving redistribution of blood flow from the internal organs to skeletal muscle, increasing cardiac function, sweating, and pupillary dilatation. Stimulation of the parasympathetic nervous system is associated with maintenance of function and conserving energy. Most of the body organs are innervated by both systems, although some organs are innervated by only one. When innervated by both systems the two systems work together allowing the body to respond appropriately to various stimuli. Disorders of the autonomic nervous system can affect any body system. They can be classed as either structural or functional disorders. Structural disorders (i.e., autonomic failure), such as multiple system atrophy (MSA) or diabetic autonomic neuropathy, exert a direct effect on autonomic nerve function whereas functional disorders do not. Functional disorders are less specific in cause and effect and are generally defined by the symptoms that an individual displays as part of a “syndrome”, such as postural tachycardia syndrome (POTS) or complex regional pain syndrome. Clinical symptoms that are associated with autonomic impairment typically include lightheadedness resulting from position changes, dry mouth, dry eyes, impotence, gastroparesis, bowel or urinary incontinence, and neuropathies, to name a few. When symptoms suggest autonomic nerve dysfunction, autonomic nerve function testing may be recommended to aid with the diagnosis of a condition. Treatment is then aimed at correction of the underlying disease and/or management of the specific symptoms. Sudomotor testing (i.e., sweat testing) is used to test nerve fibers associated with sweating and aids in the assessment of neuropathy. Cardiovagal and adrenergic testing, which are both noninvasive, use blood pressure and heart rate to obtain waveforms and measurements and are performed to evaluate conditions such as tachycardia and orthostatic hypotension. Comprehensive testing is typically performed in a dedicated autonomic testing laboratory by an autonomic disorders specialist. An evaluation typically involves an electrocardiogram (ECG), respiratory and blood pressure monitoring, and may include tilt table testing. Autonomic Sudomotor Function Tests (Sweat Testing) (CPT® code 95923) Tests that are established and commonly used to assess sudomotor function include the thermoregulatory sweat test, quantitative sudomotor axon reflex test, silastic sweat imprint test, and sympathetic skin response test. The aim of sudomotor testing is to evaluate the functional integrity of sudomotor nerves. A standardized stimulus is administered under controlled conditions, and the patient’s response is measured (Cheshire, et al., 2021). Quantitative sudomotor axon reflex test (QSART): The QSART involves stimulation of the sympathetic nerve fibers using iontophoresis of acetylcholine (ACh) and then measuring an evoked sweat response. The QSART specifically evaluates the functional status of the postganglionic sympathetic axons. The sweat response is recorded from four distinct body areas to assess for deficits, one on the forearm, and three located on the lower extremities. An absent response indicates a lesion of the postganglionic axon. Medical Coverage Policy: 0506 Thermoregulatory sweat test (TST): The TST assesses the sympathetic nerves that supply the skin and evaluates both pre- and postganglionic pathways. A color indicator in the form of powder is applied to the skin. A heat cabinet is used to raise the patient’s temperature, the elevated temperature induces sweating, and the presence of sweating causes a change in the indicator. Digital photography is used to document sweat distribution. The test can be used to diagnose neuropathy, ganglionopathy, or generalized autonomic failure. This test has also been helpful in assessing the status of dysautonomias over time. Sympathetic skin response test (SSR): The SSR test measures a change in skin resistance following a random electrical stimulation and provides an index of sweat production. Sympathetic peripheral autonomic potentials are evoked by electrical stimulation producing sweat, with recordings taken over the palms and soles. The SSR is recorded as being present or absent in the hand and in the foot. Silastic sweat imprint test: Sweat imprints are formed by the secretion of active sweat glands into a plastic/silastic imprint. This test is used to determine sweat gland density, sweat droplet size and sweat volume per area. Quantitative direct and indirect reflex test (QDIRT): The QDIRT combines some of the advantages of silicone impressions and QSART by providing data on droplet number, droplet topographic distribution, and temporal resolution in direct and axon reflex-mediated regions. Sweat glands are stimulated by acetylcholine iontophoresis and sweat is displayed via an activator dye followed by digital photographs over time. QDIRT has been associated with some limitations which include the ability to control the room temperature and humidity when and where testing is conducted. Temperature and humidity control prevents cool, dry air from causing evaporation of sweat production, which could affect the validity of test results. Quantitative pilomotor axon reflex test (QPART): The piloerector muscles generally react to mechanical, thermal, electrical, or pharmacological stimuli by way of an axon reflex (Siepmann, et al., 2012). While sudomotor axon tests and vasomotor axon tests are commonly used to evaluate small nerve fiber function, the QPART is under investigation as a method to evaluate pilomotor nerve and muscle function, which in theory can be used to complement the axon mediated tests (Siepmann, et al., 2012). Published scientific evidence supporting the clinical utility of QPART however is still being gathered. Cardiovagal Innervation (CPT code 95921) Cardiovagal testing provides a standardized quantitative assessment of vagal innervation to the heart and evaluates heart rate response to deep breathing, a Valsalva ratio, and/or heart rate response to standing. Changes in heart rate response are recorded and interpreted; when the autonomic nervous system is intact variation of heart rate occurs with the specific maneuver. These tests have high sensitivity and specificity, and are standardized established tests of autonomic function (Cheshire, et al., 2021; American Academy of Neurology [AAN], 1996). Impairment may be seen as a result of diabetic neuropathy, multiple system atrophy (formerly called Shy-Drager syndrome), idiopathic hypotension, or other neuropathies affecting the autonomic nerves. Vasomotor Adrenergic Innervation (CPT code 95922) Vasomotor adrenergic testing evaluates a beat-to-beat blood pressure response to tilt-testing, a Valsalva maneuver, or standing (e.g., Valsalva maneuver analysis). Tilt-testing results in a shift of blood to dependent body areas causing reflex responses while Valsalva maneuvers result in increased intrathoracic pressure, decreasing venous return and causing changes to blood pressure and reflex vasoconstriction. When performed these tests enhance the sensitivity and specificity of adrenergic function and are considered established methods of testing (AAN, 1996). Similar to cardiovagal testing, impairment may be seen with conditions such as multiple system atrophy, idiopathic orthostatic hypotension, and diabetic or other neuropathies affecting autonomic nerves. Combined Parasympathetic and Sympathetic Testing with Tilt Table (CPT code 95924) Combined testing of autonomic function may also be performed, and may be appropriate when there is a need to differentiate sympathetic from parasympathetic cardiovascular function. One method that is well established Medical Coverage Policy: 0506 involves testing parasympathetic function and vasomotor adrenergic function using at least a 5-minute tilt with a passive tilt table. Portable, Automated Autonomic Nerve Function Testing Devices have also been developed that allow for combined testing without the use of beat-to-beat recordings or tilt table. These devices are referred to as “automated autonomic nerve function testing” and represent a simplified method of ANS testing which has not been validated in the scientific literature, therefore results may be erroneous. These devices have been marketed as quick, office-based tests, often for use by non-ANS specialist practitioners. There are numerous commercially-available automated technologies promoted as “autonomic nervous system testing", including: ANS Sudopath Complex; Plus • ANX 3.0 • EZSCAN • Finapres® NOVA • neuropad® • Pulse 4 Pulse • Sudoscan® • TM-Flow System • VitalScan ANS; Combo Pro; SudoCheck • ZYTO Hand Cradle Automated ANS tests typically do not involve physician interpretation, or control for medications, respirations, expiratory pressures, or beat-to-beat blood pressure measurements. In the absence of expiratory pressure and blood pressure measurements in response to a Valsalva maneuver, interpretation of heart rate cannot be validated (AAN, 2014). Commercial tests which record moisture or skin conductance due to spontaneous sweating (e.g., Sudoscan®, EZSCAN) have been proposed as fast, non-invasive tests of sudomotor or sensory nerve fiber function. However, inconsistencies with technique and normative values, and concerns regarding sensitivity and specificity have been raised in the literature (Cheshire, et al., 2021; Rajan, et al., 2019). A 2021 joint professional society publication recommended ANS testing be performed in the clinical autonomic laboratory setting by healthcare professionals with comprehensive knowledge of the neuroanatomy, physiology, and pathological profiles of autonomic disorders. The statement further noted “autonomic testing by automated devices without physician interpretation has not been validated, lacks a sound physiological basis, is potentially misleading, and should be interpreted with caution.” Regarding electrochemical skin conductance-type tests, the authors stated since such tests “do not evaluate the integrity of sudomotor axons, they are not truly tests of autonomic function” (Cheshire, et al., 2021). U.S. Food and Drug Administration (FDA) Various monitoring devices have been FDA-approved for autonomic nerve function testing. Some of these devices are able to assess both branches of the nervous system, some employ automation of results, and others require physician review and interpretation. Examples of automated testing devices include but are not limited to the ANX 3.0™ (Autonomic Nervous System and Respiration [ANSAR]) (Ansar Medical Technology, Philadelphia, PA; 1995) and the VitalScan ANS (Medeia Inc., Santa Barbara, CA; 2020). Literature Review The results of clinical trials evaluating the clinical utility of autonomic nerve testing in the peer-reviewed published scientific literature are mixed, and consist of retrospective and prospective case series, observational studies and few randomized controlled trials. Some studies demonstrate that autonomic nervous system testing impacts treatment strategies and clinical outcomes while some studies show no impact (Rajan, et al., 2019; Jones and Gibbons, 2014; Iodice, et al., 2012; Kimpinski, et al., 2012; Keet, et al., 2011; Gibbons, et al., 2010; Peltier, et al., 2010; Illigens and Gibbons, 2009; Lipp, et al., 2009; Chen, et al., 2008; Wang, et al., 2008; Strickberger, et al., 2006; Hoitsma, et al., 2004; Huang, et al., 2004; Low, et al., 2004; Chelimsky, et al., 1995). Medical Coverage Policy: 0506 However, autonomic nerve function tests have been used extensively, are considered established tests that are safe and effective, and have shown clinical utility for a specific subset of conditions (Cheshire, et al., 2021). Professional Societies/Organizations Various professional societies have published recommendations supporting autonomic nerve function testing for various conditions. American Autonomic Society (AAS), American Academy of Neurology (AAN), and the International Federation of Clinical Neurophysiology (IFCN): In 2021, these societies published a consensus statement regarding the electrodiagnostic assessment of the autonomic nervous system. The recommendations included the following (Cheshire, et al., 2021): “Testing of the autonomic nervous system in the clinical autonomic laboratory should be performed by healthcare professionals with comprehensive knowledge of the neuroanatomy, physiology, and pathological profiles of autonomic disorders. Interpretation of autonomic test results should be based also on a medical history and physical examination, from which autonomic testing assists in confirming or eliminating potential conditions in a differential diagnosis. A combination of autonomic tests in a screening battery provides a more accurate measure of autonomic function, as a single test alone cannot distinguish the type or severity of autonomic failure. Ideally, assessment of autonomic function should include tests of cardiovascular adrenergic, cardiovagal, and sudomotor function. In resource-limited settings the knowledge and expertise of the person interpreting autonomic tests is no less important. Before the results are interpreted as normal or abnormal, consideration should be given to potentially confounding factors, such as medications, equipment settings, room conditions, or patient factors that might have altered the findings.” For assessment of sympathetic cardiovascular adrenergic function, the authors recommended measurement of continuous beat-to-beat heart rate and blood pressure responses to the Valsalva maneuver. Parasympathetic cardiovagal testing should include measuring continuous beat-to-beat heart rate and blood pressure responses to postural change on a tilt table; continuous beat-to-beat heart rate responses to sinusoidal deep breathing; and/or the Valsalva ratio. Assessment of sympathetic sudomotor cholinergic function should include the quantitative sudomotor axon reflex test (QSART) and/or thermoregulatory sweat test (TST). Appropriate indications for testing included: autonomic failure, including familial dysautonomia • peripheral polyneuropathy, including diabetic, amyloid, and paraneoplastic autonomic neuropathies; distal small fiber neuropathy ganglionopathy • orthostatic hypotension • orthostatic intolerance, including postural tachycardia syndrome (POTS) • • neurodegenerative disorders, including autonomic failure in multiple system atrophy, Parkinson disease, and Lewy body dementia; pure autonomic failure hyperadrenergic states • heat intolerance • regional autonomic failure The statement commented on the unproven validity of commercial tests which record moisture or skin conductance due to spontaneous sweating (e.g., Sudoscan). These tests assess sweat gland function in areas that have large sweating output, and which are highly responsive to emotional activation (e.g., palms and soles). Further, the statement noted that since such tests “do not evaluate the integrity of sudomotor axons, they are not truly tests of autonomic function.” Medical Coverage Policy: 0506 The statement further noted that “autonomic testing by automated devices without physician interpretation has not been validated, lacks a sound physiological basis, is potentially misleading, and should be interpreted with caution” (Cheshire, et al., 2021). American Association of Neuromuscular & Electrodiagnostic Medicine (AANEM): The AANEM updated its recommended policy for electrodiagnostic medicine in 2023. Within this policy, the AANEM states autonomic nervous system function testing is employed to determine the presence of autonomic dysfunction, to determine the site of autonomic function and to identify various autonomic systems which may be disordered. The recommended policy includes testing of cardiovagal innervation, vasomotor adrenergic innervation, and evaluation of sudomotor function (specifically, the quantitative sudomotor axon reflex test [QSART]; silastic sweat imprint; thermoregulatory sweat test; and sympathetic skin response [SSR]). Conditions for which testing may be appropriate included as multiple system atrophy, idiopathic orthostatic hypotension, diabetic neuropathy, and other neuropathies affecting autonomic nerves. In 2021, the AANEM published a revised position statement on the proper performance of autonomic function testing. The statement outlined the qualifications and training of the provider performing such studies, specifically that the provider “must be a physician with special training in the diagnosis and treatment of disorders of the autonomic nervous system and in the application of particular neurophysiological techniques to study these disorders.” The AANEM statement recommended the following tests as reliable and reproducible: Evaluation of sudomotor function: o quantitative sudomotor axon reflex testing o o o sympathetic skin response • Evaluation of cardiovagal function: thermoregulatory sweat testing induced silastic skin imprints o heart rate response to deep breathing o Valsalva ratio o postural change Evaluation of vasomotor adrenergic function: o continuous beat-to-beat heart rate and blood pressure response to a Valsalva maneuver o tilt table test o active standing Pharmacologic testing to induce changes in blood pressure was not recommended. The AANEM further stated the physician should consider other factors that may cause abnormal test results (e.g., beat-to-beat blood pressure setting; room temperature and humidity; tobacco, caffeine or medication use; patient participation). Finally, the statement noted the physician “should directly supervise and interpret the data on-site and in real time collected in various autonomic procedures including those performed by a technician” (AANEM, 2021). American Heart Association (AHA) and American College of Cardiology Foundation (ACCF): These organizations published a scientific statement on the evaluation of syncope (Strickberger, et al., 2006) that includes autonomic testing to confirm the presence of a dysautonomia, to distinguish central from peripheral causes, and to guide patient management. Autonomic tests included in the recommendations are tilt table testing, cardiac responses to deep breathing and the Valsalva maneuver, and sweat testing. Use Outside of the US National Institute for Health and Care Excellence (NICE; United Kingdom): The 2022 NICE guidance on the use of Neuropad for detecting preclinical diabetic peripheral neuropathy indicated there was insufficient evidence to support the use of Neuropad in persons for whom standard (10 g monofilament) testing is not possible. Medical Coverage Policy: 0506