Search all medical codes

Auditory evoked potentials; for threshold estimation at multiple frequencies, with interpretation and report

CPT4 code

Name of the Procedure:

Auditory Evoked Potentials (AEP); Threshold Estimation at Multiple Frequencies, with Interpretation and Report

Summary

Auditory Evoked Potentials (AEP) are tests that measure the brain's electrical responses to sounds. This specific procedure aims to determine the softest sound levels that a person can hear across different frequencies. It is a non-invasive test often used for people who cannot participate in traditional hearing tests.

Purpose

AEP testing helps diagnose hearing loss and auditory nerve function problems. It is particularly useful for infants, young children, or individuals who are unable to provide reliable responses in a conventional hearing test. The goal is to accurately assess hearing thresholds to guide further treatment or intervention.

Indications

  • Suspected hearing loss in newborns, infants, and very young children
  • Uncooperative or non-verbal patients
  • Monitoring auditory nerve and brainstem function
  • Diagnosing auditory neuropathy or auditory processing disorders

Preparation

  • No special preparation is usually required, but keep the ears clean and free of excessive earwax.
  • Inform the patient or caregivers to minimize caffeine intake for 24 hours before the test.
  • Ensure the patient is rested, as they might need to be quiet and lie still or even asleep during the procedure.

Procedure Description

  1. Small electrodes are placed on the scalp and behind the ears after cleaning the skin with a mild abrasive gel.
  2. Earphones or inserts are placed in the ear canals.
  3. The patient is exposed to a series of sounds or clicks at various frequencies and volumes.
  4. The electrodes measure the electrical activity in response to these sounds.
  5. A computer records and analyzes this data to estimate hearing thresholds.
  6. The audiologist interprets the results and prepares a detailed report.

Duration

The procedure typically takes about 1 to 2 hours, depending on the patient's cooperation and specific testing requirements.

Setting

Performed in an audiology lab, hospital, outpatient clinic, or specialized testing center.

Personnel

  • Audiologist
  • Trained technicians
  • Sometimes a neurologist may be involved for interpretation of complex cases

Risks and Complications

  • Generally considered very safe with minimal risks
  • Rarely, skin irritation from electrode placement
  • Mild discomfort from earphone inserts or electrode application

Benefits

  • Accurate hearing threshold detection across multiple frequencies
  • Essential for early diagnosis and treatment of hearing loss, especially in young children
  • Can guide intervention planning, such as hearing aids or cochlear implants

Recovery

  • No special recovery measures are required.
  • Patients can typically resume normal activities immediately after the test.
  • Follow-up appointments may be necessary to discuss results and plan further care.

Alternatives

  • Traditional behavioral audiometry tests
  • Otoacoustic emissions (OAEs) testing
  • Pure tone audiometry
  • Each alternative has its own set of pros and cons. For example, traditional methods may require patient cooperation and may not be suitable for infants or those with severe developmental delays.

Patient Experience

  • The procedure is painless and non-invasive.
  • Some mild discomfort may be experienced from the electrodes or earphones.
  • The patient needs to lie still and may be required to sleep during the test.
  • Comfort measures such as warm blankets or a quiet environment can help make the experience more pleasant.

Similar Codes