Humana Ventricular Assist Device, Total Artificial Heart - Medicare Advantage Form


Effective Date

01/01/2024

Last Reviewed

NA

Original Document

  Reference



Please refer to CMS website for the most current applicable National Coverage Determination (NCD)/ Local Coverage Determination (LCD)/Local Coverage Article (LCA)/CMS Online Manual System/Transmittals.

Type
Title
ID Number
Jurisdiction Medicare
Applicable States/Territories

Ventricular Assist Device, Total Artificial Heart Page: 2 of 18

Administrative Contractors (MACs)
  • NCD
  • Ventricular Assist Devices Artificial Hearts and Related Devices
  • 20.9.1 65-15
  • LCA
  • Billing and Coding: Artificial Hearts and Percutaneous Endovascular Cardiac Assist Procedures and Devices
  • A52966 ———
  • - JE - Noridian Healthcare Solutions, LLC
  • CA, HI, NV, American Samoa, Guam Northern Mariana Islands
  • LCA
  • Billing and Coding: Artificial Hearts and Percutaneous Endovascular Cardiac Assist Procedures and Devices
  • A52967
  • JF - Noridian Healthcare Solutions, LLC
  • AK, AZ, ID, MT, ND, OR, SD, UT, WA, WY
  • LCA
  • Billing and Coding: Percutaneous Ventricular Assist Device
  • A53986
  • JJ - Palmetto GBA (Part A/B MAC)
  • AL, GA, TN
  • JM - Palmetto GBA (Part A/B MAC)
  • NC, SC, VA, WV

Description

Ventricular Assist Device

A ventricular assist device (VAD) is a mechanical pump that compensates for the diminished ability of a weakened heart, by assisting or replacing the function of the left or right ventricle. A left VAD (the most commonly used) provides blood flow throughout the body while the right VAD supports the pulmonary (lung) circulation. VADs may be utilized for an individual suffering from reversible cardiac dysfunction, to support an individual who is awaiting heart transplantation or to provide permanent circulatory support with end-stage heart failure (HF) in those who are not a candidate for transplantation (known as destination therapy).

There are many VADs available for use. Important characteristics of these systems include: location of the pumping chamber, the specific ventricles that are supported, the pumping mechanism and how long support (temporary or long-term) is indicated.

Typically, short-term devices are extracorporeal (located outside the body) and long-term use are implantable systems. Generally these devices are placed via a sternotomy; however, some have received US Food & Drug Administration (FDA) approval for placement via a thoracotomy (eg, HeartMate 3).

FDA-approved VADs include, but may not be limited to, the following:

  • Bridge to transplant: CentriMag Circulatory Support System, HeartMate II LVAD, HeartMate 3 LVAD.
  • Destination therapy: HeartMate II LVAD, HeartMate 3 LVAD.
  • Short-term bridge to recovery: CentriMag Circulatory Support System, HeartMate 3 LVAD.

The HeartWare HVAD has been voluntarily recalled by the manufacturer due to neurological complications with the device and is no longer being sold/distributed.

Percutaneous ventricular assist devices (pVADs) differ from other types of VADs as they can be placed via cardiac catheterization without the need for open-chest surgery, which avoids potential difficulties in crossing the aortic valve.

pVADs are utilized for short-term bridge to recovery (eg, less than or equal to 4 hours for Impella 2.5 and Impella CP with SmartAssist, less than or equal to 6 hours for Impella 5.0/LD, LifeSPARC system and TandemHeart and up to 14 days for the Impella 5.5 with SmartAssist). Examples of pVADs include, but may not be limited to:

  • Aortix Percutaneous Mechanical Circulatory Support (pMCS) (Refer to Coverage Limitations section)
  • Impella 2.5 System
  • Impella 5.0 (LP/LD)
  • Impella 5.5 with SmartAssist*
  • Impella CP with SmartAssist*
  • LifeSPARC system
  • TandemHeart*

*SmartAssist technology is designed to provide physicians with weaning algorithms as well as additional data such as left ventricular (LV) pressure, end diastolic pressure and cardiac output with the intent of optimizing survival and recovery. The data can be accessed via an online database.

The CentriMag Circulatory Support System is indicated for temporary circulatory support for up to 30 days for one or both sides of the heart to treat postcardiotomy individuals who fail to wean from cardiopulmonary bypass. This provides a bridge to decision when it is unclear whether the individual’s heart will recover or whether the individual will need alternative, longer-term therapy.

The Impella RP System is indicated for providing temporary right ventricular support for up to 14 days in individuals with a body surface area ≥1.5 m2, who develop acute right heart failure or decompensation for less than 48 hours following left ventricular assist device implantation, myocardial infarction, heart transplant, or open‐heart surgery, without the presence of profound shock, end organ failure, or acute neurologic injury. In addition, the Impella RP Flex is implanted via the internal jugular (IJ) vein, which purportedly enables patient mobility, and has dual-sensor technology designed to optimize patient management.

Total Artificial Heart

A total artificial heart (TAH) is a device that replaces the two lower chambers of the heart and is available to individuals with end-stage heart failure.

The SynCardia temporary TAH-t is intended for an individual who is on a heart transplant list and are so critically ill that death is imminent without use of this as a bridge until a heart transplant is available. The SynCardia TAH-t is an implantable device that is driven by compressed air and replaces the function of the ventricles.

It attaches to the individual’s atria after the damaged ventricles are removed.

Each ventricle of the TAH is connected to a driveline that is tunneled through the chest wall and attached to an external bedside console that supplies pulses of pneumatic pressure to the left and right drivelines, which are connected to the air chambers of their respected ventricles. These air pulses distend the diaphragms ejecting blood from the left ventricle and right ventricle synchronously to the systemic and pulmonary circulation.44 The SynCardia 70cc TAH-t is intended to support individuals with a body surface area (BSA) greater than or equal to 1.7m2. The 50cc TAH-t is also available, which is designed for an individual that is smaller in stature with a BSA less than or equal to 1.85m2.

Traditionally, artificial heart technology has used large, hospital-based pneumatic driver systems, which require an individual to be hospitalized while awaiting a donor heart. However, the Freedom portable driver has been developed, which purportedly enables a stable individual to be discharged from the hospital to await a suitable donor heart at home.

Permanently implantable aortic counterpulsation ventricular assist devices as a bridge to recovery are being investigated using surgically implanted counterpulsation devices that are placed in or around the aorta. This treatment is based on the scientific principle of an intraaortic balloon pump (IABP) that provides counterpulsation, which is theorized to stimulate the work and reduce the afterload of the left ventricle. There are currently no FDA-approved continuous internal pulsation devices. Examples of devices in development or in clinical trials include, but may not be limited to: CardioVAD, C-pulse heart assist system, NuPulse iVAS, PULVAD device and the Symphony counterpulsation device.52

Coverage Determination

Humana follows the CMS requirements that only allows coverage and payment for services that are reasonable and necessary for the diagnosis and treatment of illness or injury or to improve the functioning of a malformed body member except as specifically allowed by Medicare.

Please refer to the above CMS guidance for Ventricular Assist Devices for Bridge to Transplant and Destination Therapy.

In interpreting or supplementing the criteria above and in order to determine medical necessity consistently, Humana may consider the following criteria:

  • Percutaneous insertion of an FDA-approved endovascular cardiac assist device (pVAD), when external counterpulsation (IABP) is not expected to be sufficient, will be considered medically reasonable and necessary when the following indications are met:
  • Ventricular Assist Device, Total Artificial Heart Page: 5 of 18
  • Cardiogenic shock
  • Severe decompensated heart failure with threatening multi-organ failure
  • Complications/disturbance of the circulatory system intra-operatively or postoperatively

Facilities must be credentialed by an organization approved by CMS. The process for organizations to apply for CMS approval to be designated as a credentialing organization for LVAD facilities is posted on the CMS site along with a list of approved credentialing organizations, approved standard versions, and credentialed facilities: http://www.cms.gov/Medicare/Medicare-General-Information/MedicareApprovedFacilitie/VAD-Destination-Therapy-Facilities.html

The use of the criteria in this Medicare Advantage Medical Coverage Policy provides clinical benefits highly likely to outweigh any clinical harms. Services that do not meet the criteria above are not medically necessary and thus do not provide a clinical benefit. Medically unnecessary services carry risks of adverse outcomes and may interfere with the pursuit of other treatments which have demonstrated efficacy.

Coverage Limitations

US Government Publishing Office.

Electronic code of federal regulations: part 411 – 42 CFR § 411.15 - Particular services excluded from coverage

The following tests will not be considered medically necessary and reasonable17:

  • pVAD
  • TAH
  • VAD

From 20.9.1:

C. Nationally Non-Covered Indications.

All other indications for the use of VADs not otherwise listed remain non-covered, except in the context of Category B investigational device exemption clinical trials (42 CFR 405) or as a routine cost in clinical trials defined under section 310.1 of the National Coverage Determinations (NCD) Manual.17

The following cardiac support devices/systems will not be considered medically reasonable and necessary:

  • Aortix pMCS device
  • Permanently implantable aortic counterpulsation ventricular assist device
  • SynCardia freedom driver system

A review of the current medical literature shows that the evidence is insufficient to determine that these services are standard medical treatments. There remains an absence of randomized, blinded clinical studies

Ventricular Assist Device, Total Artificial Heart Page: 6 of 18

examining benefit and long-term clinical outcomes establishing the value of these services in clinical management.

Summary of Evidence

Aortix pMCS Device

There is no published evidence evaluating the use of Aortix for acute decompensated heart failure (ADHF). Additional larger clinical studies that evaluate its use in patients with ADHF are necessary to determine its safety, effectiveness, and clinical utility in treating ADHF and cardiorenal syndrome. Aortix is also under investigation to prevent renal complications in patients undergoing cardiovascular surgery who are at increased risk of acute kidney injury (AKI); the first patients were enrolled and treated in late February 2023.33

Additionally, there are no position statements or guidelines addressing the use of the Aortix device.

Permanently Implantable Aortic Counterpulsation Ventricular Assist Device

Evidence regarding counterpulsation devices were recorded in the World Journal of Transplantation as urgently requiring additional experimental and clinical studies to better characterize their role in HF.52

SynCardia Freedom Driver System

Very little published evidence was available regarding the use of portable drivers with the TAH.44