Search all medical codes

Transmitter cable for use with cochlear implant device or auditory osseointegrated device, replacement

HCPCS code

Name of the Procedure:

Transmitter Cable Replacement for Cochlear Implant or Auditory Osseointegrated Device
Common names: Cochlear implant cable replacement, BAHA (bone-anchored hearing aid) cable replacement
Technical/medical term: L8618

Summary

Replacing the transmitter cable of a cochlear implant or auditory osseointegrated device is a straightforward procedure designed to ensure the optimal functioning of hearing devices when the original cable gets damaged or becomes faulty.

Purpose

This procedure addresses issues of malfunctioning or broken transmitter cables in cochlear implants or auditory osseointegrated devices, which are essential for transmitting sound signals.
The goal is to restore proper hearing capabilities for the patient by replacing the faulty cable, thereby maintaining the efficacy of the hearing device.

Indications

  • Noticeable decline in hearing quality associated with a faulty cable
  • Documented damage or wear and tear of the transmitter cable
  • Device alerts or diagnostics indicating a need for cable replacement
  • Patients struggling with connectivity issues between the external processor and the implanted device

Preparation

  • No significant fasting or dietary restrictions are required.
  • Regular medications can generally continue, but it's always best to consult with your audiologist or physician.
  • Diagnostic tests might include checking the device's connectivity and performance to confirm the cable is the issue.

Procedure Description

  1. Assessment: An audiologist will initially assess the hearing device to confirm the cable is faulty.
  2. Preparation: The patient may be asked to sit comfortably in a chair.
  3. Replacement Process:
    • The old or damaged transmitter cable is carefully disconnected from the external processor and the attachment point near the ear or implant site.
    • The new, compatible transmitter cable is then carefully connected, ensuring all connections are secure.
  4. Testing: Once the new cable is in place, the device is tested to ensure proper functionality.
  5. Final Adjustments: Any necessary adjustments to the settings of the hearing device are made to optimize hearing quality.

Duration

Typically, the procedure takes around 15 to 30 minutes.

Setting

This is usually performed in an outpatient setting, such as an audiologist's office or a specialized hearing clinic.

Personnel

  • Audiologist
  • Support staff, if necessary

Risks and Complications

  • Common Risks: Slight discomfort or irritation at the attachment points, minor alignment issues that need readjustment.
  • Rare Risks: Damage to the device components during handling, temporary degradation in sound quality.

Benefits

  • Restored and improved hearing performance.
  • Immediate improvement often noticed once the procedure is completed.
  • Extended lifespan of the hearing device by addressing connectivity issues.

Recovery

  • Minimal, if any, recovery time needed.
  • Post-procedure instructions typically involve routine care of the device and monitoring for any issues over the first few days.
  • Follow-up appointments scheduled for a few weeks post-procedure to ensure ongoing device function.

Alternatives

  • Non-Surgical: Regular maintenance and cleaning of the existing cable to prolong its life until replacement becomes unavoidable.
  • Surgical: Full device replacement if multiple components fail, although this is rare and typically a last resort.

Patient Experience

During the procedure, the patient may feel a slight tugging or disconnecting sensation as the old cable is removed, but this is generally painless. After the replacement, a brief period of getting used to the new cable's fit and function might occur. Most patients experience a significant and immediate improvement in hearing clarity once the procedure is complete. Audiologists often provide guidance on pain management and comfort measures, though they are seldom needed for this straightforward procedure.

Medical Policies and Guidelines for Transmitter cable for use with cochlear implant device or auditory osseointegrated device, replacement

Related policies from health plans

Similar Codes