Search all medical codes

Ultrasonic guidance for amniocentesis, imaging supervision and interpretation

CPT4 code

Name of the Procedure:

Ultrasonic guidance for amniocentesis, imaging supervision and interpretation.

Summary

In this procedure, an ultrasound is used to guide a needle into the uterus to collect a small sample of amniotic fluid. This sample can be tested for genetic conditions and other fetal health concerns.

Purpose

Amniocentesis addresses the need for accurate prenatal diagnosis of genetic disorders, fetal infections, and certain birth defects. The goal is to provide essential information about the fetus's health to assist in making informed medical and personal decisions.

Indications

Specific symptoms or conditions that may warrant the procedure include:

  • Advanced maternal age (35 years or older).
  • Family history of genetic disorders.
  • Abnormal results from other prenatal tests.
  • Previous child with a genetic condition.
  • Concerns over fetal infections or Rh sensitization.

Preparation

Patients may be advised to:

  • Consume a light meal prior to the procedure.
  • Avoid heavy lifting or strenuous activity the day before.
  • Undergo an ultrasound scan to locate the fetus and placenta.
  • Have a full bladder, depending on the gestational age.

Procedure Description

  1. The patient lies on an examination table.
  2. A healthcare professional applies a special gel to the patient's abdomen and uses an ultrasound device to locate the fetus and placenta.
  3. The skin on the abdomen is cleaned and may be numbed with a local anesthetic.
  4. Under continuous ultrasound guidance, a thin needle is carefully inserted through the abdominal wall and into the amniotic sac to withdraw a small amount of amniotic fluid.
  5. The collected fluid is sent to a laboratory for analysis.
  6. The needle is then removed, and the site is cleaned.

Duration

The procedure typically takes about 30 minutes to 1 hour, including preparatory steps.

Setting

Ultrasonic guidance for amniocentesis is usually performed in a hospital, outpatient clinic, or specialized prenatal center.

Personnel

The procedure involves:

  • A radiologist or maternal-fetal medicine specialist to perform the ultrasound.
  • An obstetrician or trained clinician to perform the amniocentesis.
  • Nursing staff to assist and provide care.

Risks and Complications

Risks include:

  • A small risk of miscarriage (about 1 in 200 to 1 in 400 procedures).
  • Cramping, bleeding, or leaking amniotic fluid.
  • Infection or injury to the fetus, placenta, or nearby organs. Complications are managed by monitoring and supportive care.

Benefits

The primary benefit is the accurate diagnosis of genetic and chromosomal abnormalities, allowing for early intervention, planning, and peace of mind. Results are typically available within 1-2 weeks.

Recovery

Post-procedure care includes:

  • Resting for the remainder of the day and avoiding strenuous activity for 24-48 hours.
  • Monitoring for any signs of complications such as heavy bleeding, fluid leakage, or fever.
  • Follow-up appointment as advised by your healthcare provider.

Alternatives

Possible alternatives include:

  • Non-invasive prenatal testing (NIPT): A blood test that screens for common genetic conditions.
  • Chorionic villus sampling (CVS): A procedure similar to amniocentesis performed earlier in pregnancy. Pros and cons:
  • NIPT is less invasive but may not provide as comprehensive information as amniocentesis.
  • CVS offers earlier results but has a slightly higher risk of miscarriage.

Patient Experience

During the procedure, patients might feel slight pressure or cramping when the needle is inserted. After the procedure, mild discomfort or cramping may occur, which can generally be managed with over-the-counter pain relief and rest. Emotional support and clear communication from the healthcare team enhance the overall experience.

Similar Codes